Affiliation:
1. National Bureau of Standards U.S. Department of Commerce
Washington, D.C. 20234
Abstract
An error analysis is given for the 1-meter Guarded Hot Plate at the National Bureau of Standards. This apparatus is used to measure the thermal resistance of insulation materials. The individual contributions to uncertainty in thermal resistance are discussed in detail. The total uncertainty is estimated to be less than 0.5 percent at sample thicknesses up to 150 mm (6 inches) and less than 1 percent at a thickness of 300 mm (12 inches).
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献