Octyl-butyl-cyanoacrylate glue for securement of peripheral intravenous catheters: A retrospective, observational study in the neonatal population

Author:

van Rens Matheus FPT1ORCID,Spencer Timothy R2ORCID,Hugill Kevin3,Francia Airene LV1,van Loon Fredericus HJ45ORCID,Bayoumi Mohammad AA1ORCID

Affiliation:

1. Women’s Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar

2. Global Vascular Access LLC, Scottsdale, AZ, USA

3. Department of Nursing and Midwifery Education, Hamad Medical Corporation, Doha, Qatar

4. Anesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands

5. PeriOperative Care & Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands

Abstract

Background: Evidence-based insertion and maintenance strategies for neonatal vascular access devices (VAD) exist to reduce the causes of VAD failure and complications in neonates. Peripheral intravenous catheter failure and complications including, infiltration, extravasation, phlebitis, dislodgement with/without removal, and infection are majorly influenced by catheter securement methods. Methods: A retrospective, observational study using routinely collected data on intravenous device use in a large neonatal intensive care unit in Qatar. A 6-month historical cohort was compared with a 6-month cohort after the introduction of an octyl-butyl-cyanoacrylate glue (CG). In the historical cohort, the catheter was secured using a semi-permeable transparent membrane dressing while in the CG cohort, CG was applied at the insertion site on initial insertion and after any dressing change. This was the only variable intervention between both groups. Results: A total of 8330 peripheral catheters were inserted. All catheters were inserted and monitored by members of the NeoVAT team. 4457 (53.5%) were secured with just a semi-permeable transparent dressing and 3873 (46.5%) secured a semi-permeable transparent dressing with the addition of CG. The odds ratio for premature failure after securement with CG was 0.59 (0.54–0.65) when compared to the catheters secured with a semi-permeable transparent dressing, which was statistically significant ( p < 0.001). The correlation between the occurrence of a complication and the use of CG for device securement was significant ( p < 0.001). Conclusions: The risk of developing device-related phlebitis and premature device removal, increased significantly if CG was not used for adjunct catheter securement. In parallel with the currently published literature, this study’s findings support the use of CG for vascular device securement. When device securement and stabilization concerns are most pertinent CG is a safe and effective adjunct to reducing therapy failures in the neonatal patient population.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3