The impact of stent-graft sizing on venous stenosis re-intervention and arteriovenous graft patency: Free-floating stent outflow is associated with improved outcomes

Author:

Stove Callum1ORCID,Kingsmore David B23,Stevenson Karen S3,Thomson Peter C4ORCID,Nath Alex1,Kasthuri Ram1

Affiliation:

1. Interventional Radiology, Queen Elizabeth University Hospital, Glasgow, UK

2. Vascular and Endovascular Surgery, Queen Elizabeth University Hospital, Glasgow, UK

3. Renal and Transplant Surgery, Queen Elizabeth University Hospital, Glasgow, UK

4. Nephrology, Queen Elizabeth University Hospital, Glasgow, UK

Abstract

Background: Early cannulation arteriovenous grafts (ecAVG) for dialysis access are limited by reintervention for venous stenosis (VS) despite their good initial patency. Whilst stent-grafts (SG) have shown promise, the optimal sizing is unclear. Therefore, this study aims to determine if outflow vein diameter, SG diameter or these relative to each other (V:Sr) alters outcomes, and if so, which is more important. Methods: Retrospective analysis was performed of Gore® Acuseal® ecAVGs with VS treated with Gore® Viabahn® SG over a 7-year period. Primary patency (PP), time to thrombosis and functional patency were analysed by SG length/diameter, vein diameter and V:Sr. Results: We identified 114 ecAVGs with median follow-up 492 days (IQR 189–770). SG length and diameter did not correlate with PP, however, there was a significant relationship between vein diameter and PP (RR = 0.901 (0.832–0.975), p = 0.01) and between V:Sr and PP (RR = 0.462 (0.255–0.838), x2 = 5.866, p = 0.0015). The optimal V:Sr was ⩾1.4 (i.e. vein diameter at least 40% greater than the stent-graft; or ‘free-floating’ stent outflow) (RR = 2.759 (1.670–4.558), p < 0.001), translating to a difference in median PP of 252 versus 496 days (IQR: 188–316; 322–670). On multivariate analysis, absolute vein diameter lost significance, whilst V:Sr remained an independently significant predictor of PP (RR = 3.247 (1.560–6.759), p = 0.02). Conclusions: Placement of the SG outflow into a relatively larger segment of vein was associated with a significant increase in PP independent of the absolute vein diameter. This suggests that larger calibre SG which are apposed to the vein wall are not required for optimal primary patency, and indeed should be actively avoided. Instead, a ‘free-floating’ stent outflow which is undersized relative to the recipient vein (whilst maintaining a minimum anchoring calibre) is recommended where possible. This should be considered during intervention and may require selection of longer devices, where practical, to bring the stent outflow into a larger vein segment. Level of Evidence: Level 3a, Non-randomised controlled cohort/follow-up study

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Stent graft effective irrespective of length of VAIVT interval;Nihon Toseki Igakkai Zasshi;2024

2. 6.アクセス;Nihon Toseki Igakkai Zasshi;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3