Ultrasound-guided access to the axillary vein for implantation of cardiac implantable electronic devices: A systematic review and meta-analysis

Author:

D’Arrigo Sonia1ORCID,Perna Francesco2,Annetta Maria Giuseppina1,Pittiruti Mauro3ORCID

Affiliation:

1. Department of Anesthesia and Intensive Care, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy

2. Department of Cardiovascular Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy

3. Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy

Abstract

The aims of our systematic review were to quantify the expected rate of procedural success, early and late complications during CIED implantation using US-guided puncture of the axillary vein and to perform a meta-analysis of those studies that compared the US technique (intervention) versus conventional techniques (control) in terms of complication rates. MEDLINE, ISI Web of Science, and EMBASE were searched for eligible studies. Pooled Odds Ratio (OR) and Pooled Mean Difference (PMD) for each predictor were calculated. The quality of evidence (QOE) was evaluated according to the GRADE guidelines. Thirteen studies were included a total of 2073 patients. The overall success of US-guided venipuncture for CIED implantation was 96.8%. As regards early complications, pneumothorax occurred in 0.19%, arterial puncture in 0.63%, and severe hematoma/bleeding requiring intervention in 1.1%. No cases of hemothorax, brachial plexus, or phrenic nerve injury were reported. As regards late complications, the incidence of pocket infection, venous thromboembolism, and leads dislodgement was respectively 0.4%, 0.8%, and 1.2%. In the meta-analysis (five studies), the intervention group (US-guided venipuncture) had a trend versus a lower likelihood of having a pneumothorax (0.19% vs 0.75%, p = 0.21), pocket hematoma (0.8% vs 1.7%, p = 0.32), infection (0.28% vs 1.05%, p = 0.29) than the control group, but this did not reach statistical significance. The overall QOE was low or very low. In conclusions we found that the US-guided axillary venipuncture for CIEDs implantation was associated with a low incidence of early and late complications and a steep learning curve.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3