Accuracy and reliability of perception of bar velocity loss for autoregulation in resistance exercise

Author:

da Silva Drumond Gilo1,da Silva Rodrigo Fabio Bezerra1ORCID,Gantois Petrus2ORCID,Nascimento Vitor Bertoli3,Nakamura Fábio Yuzo4,Fonseca Fabiano de Souza15

Affiliation:

1. Department of Physical Education, Graduate Program in Physical Education Federal University of Pernambuco, Recife, Brazil

2. Associate Graduate Program in Physical Education UPE/UFPB, João Pessoa, Brazil

3. Department of Physical Education, Paraná Federal University, Curitiba, Brazil

4. Research Center in Sports Sciences, Health Sciences, and Human Development (CIDESD), University of Maia (ISMAI), Maia, Portugal

5. Department of Physical Education, Federal Rural University of Pernambuco, Recife, Brazil

Abstract

Background The perception of bar velocity loss (PVL) can be used as an alternative method for autoregulating intraset repetitions during velocity-based training. This study analyzed the accuracy and reliability of the PVL as a method to autoregulate the intraset repetitions using a moderate velocity loss (VL) threshold (15–30%). Methods A total of 22 resistance-trained men were familiarized with the PVL in a single session. Test–retest was performed in two sessions 1 week apart, in which participants completed three sets of bench press and back squat at 40, 60, and 80% 1 repetition maximum (1RM). Participants stopped the sets when they reached a moderate VL zone using their PVL. Accuracy was assessed by analyzing whether the mean VL (actual) and the lower and upper limits of the confidence interval (CI) (95%) of each set were within the established VL range and quantifying the relative frequency of correctly interrupted sets. Test–retest reliability was examined by the intraclass correlation coefficient and coefficient of variation. Results PVL showed acceptable accuracy in both exercises at 60 and 80% 1RM (50–65% success rate) and retest for all loads (53–76% success rate). Similar PVL percentages were observed between most of the sets for the test and retest ( p > 0.05). Accuracy improved during the retest, especially for bench press (40% 1RM) and back squat (40 and 80% 1RM). PVL was not reliable in the test–retest comparison. Conclusion PVL can be a strategy with acceptable accuracy to autoregulate the intraset repetitions in a moderate zone (VL15–30%), but its reliability does not appear satisfactory after one familiarization session.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3