Guidelines for reducing image retakes of general digital radiography

Author:

Lin Chih-Sheng12,Chan Po-Chou3,Huang Kuang-Hua1,Lu Chun-Feng4,Chen Yung-Fu156,Lin Chen Yun-O7

Affiliation:

1. Department of Health Services Administration, China Medical University, Taichung, Taiwan

2. Department of Radiology, BenQ Medical Center, Nanjing, China

3. Department of Management Information Systems, Central Taiwan University of Science and Technology, Taichung, Taiwan

4. Department of Electrical Engineering and Energy Technology, Chung Chou University of Science and Technology, Changhua, Taiwan

5. Department of Dental Technology and Materials Science, Central Taiwan University of Science and Technology, Taichung, Taiwan

6. Department of Healthcare Administration, Central Taiwan University of Science and Technology, Taichung, Taiwan

7. Department of Gynecology and Obstetrics, Lin Shin Hospital, Taichung, Taiwan

Abstract

Image retake of radiological examinations not only increases the risk of radiation exposure of the patients, but also wastes the medical resource and degrades the quality of services of the hospitals. This study aimed at discovering factors affecting image retake of general digital radiography for setting guidelines to reduce the image retaking rate. A total of 98,503 general X-ray images retrieved from the picture archiving and communication system database of a medical center in central Taiwan were analyzed. The results showed that the total retaking rate was 4.89% with the position error (56.05%) was the main factor causing image retakes and chest examination showed the highest frequency (1544 cases). On the other hand, skull/face exhibited the highest retaking rate (9.81%) among various types of examinations. After discovering the factors affecting the image retaking rate, suitable guidelines were proposed and introduced. The image retake rate had been significantly reduced to 4.38% and 3.57% 1 month and 6 months, respectively, after the introduction of guidelines. In conclusion, image retake analysis is a quality indicator and is effective for quality assurance of digital radiology. Regular analysis of image retake can find factors inducing image retake and is useful for designing guidelines to reduce the image retake rate.

Publisher

SAGE Publications

Subject

Mechanical Engineering

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3