Definition, estimation and decoupling of the overall uncertainty of the outdoor air temperature measurement surrounding a building envelope

Author:

Giraldo-Soto Catalina1ORCID,Erkoreka Aitor1ORCID,Mora Laurent2,Uriarte Amaia3,Eguía-Oller Pablo4,Gorse Christopher5

Affiliation:

1. ENEDI research group, Energy Engineering Department, Faculty of Engineering of Bilbao, University of Basque Country UPV/EHU, Bilbao, Pl. Ingeniero Torres Quevedo 1, Spain

2. I2M – Institute of Mechanics and Engineering, University of Bordeaux CNRS (UMR 5295), Site ENSAM, Esplanade des Arts et Métiers, Talence, France

3. TECNALIA, Basque Research and Technology Alliance (BRTA), Edificio 700 Parque Tecnológico de Bizkaia, Derio, Spain

4. Department of Mechanical Engineering, Heat Engines and Fluids Mechanics, Industrial Engineering School, University of Vigo (Universidade de Vigo), Vigo, Spain

5. School of Architecture Building & Civil Engineering, Loughborough University, Leicestershire, UK

Abstract

Outdoor air temperature represents a fundamental physical variable that needs to be considered when characterising the energy behaviour of buildings and its subsystems. Research, for both simulation and monitoring, usually assumes that the outdoor air temperature is homogeneous around the building envelope, and when measured, it is common to have a unique measurement representing this hypothetical homogeneous outdoor air temperature. Furthermore, the uncertainty associated with this measurement (when given by the research study) is normally limited to the accuracy of the sensor given by the manufacturer. This research aims to define and quantify the overall uncertainty of this hypothetical homogeneous outdoor air temperature measurement. It is well known that there is considerable variability in outdoor air temperature around the building and measurements are dependent on the physical location of outdoor air temperature sensors. In this research work, this existing spatial variability has been defined as a random error of the hypothetical homogeneous outdoor air temperature measurement, which in turn has been defined as the average temperature of several sensors located randomly around the building envelope. Then, some of these random error sources which induce spatial variability would be the cardinal orientation of the sensor, the incidence of solar radiation, the outdoor air temperature stratification, the speed and variations of the wind and the shadows of neighbouring elements, among others. In addition, the uncertainty associated with the systematic errors of this hypothetical homogeneous outdoor air temperature measurement has been defined as the Temperature Sensor Uncertainty [Formula: see text] where this uncertainty is associated with the sensor’s accuracy. Based on these hypotheses, a detailed statistical procedure has been developed to estimate the overall Temperature Uncertainty [Formula: see text]) of this hypothetical homogeneous outdoor air temperature measurement and the Temperature Sensor Uncertainty [Formula: see text]. Finally, an uncertainty decoupling method has also been developed that permits the uncertainty associated with random errors (Temperature’s Spatial Uncertainty [Formula: see text]) to be estimated, based on [Formula: see text] and [Formula: see text] values. The method has been implemented for measuring the outdoor air temperature surrounding an in-use tertiary building envelope, for which an exterior monitoring system has been designed and randomly installed. The results show that the overall Temperature Uncertainty [Formula: see text] for the whole monitored period is equal to ±2.22°C. The most notable result is that the uncertainty associated with random errors of measurement (Temperature’s Spatial Uncertainty [Formula: see text]) represents more than 99% of the overall uncertainty; while the Temperature Sensor Uncertainty [Formula: see text], which is the one commonly used as the overall uncertainty for the outdoor air temperature measurements, represents less than 1%.

Funder

Euskal Herriko Unibertsitatea

Eusko Jaurlaritza

Ministerio de Ciencia, Innovación y Universidades

Publisher

SAGE Publications

Reference40 articles.

1. a2pbeer.eu. Affordable and Adaptable Public Buildings through Energy Efficient Retrofitting (A2PBEER). Available at: https://cordis.europa.eu/project/id/609060/news/es (accessed 6 August 2024). (accessed 10 May 2024).

2. Co-heating test: A state-of-the-art

3. BIPM. Guide to the expression of uncertainty in measurement (GUM). Available at: https://www.bipm.org/en/publications/guides/gum.html (accessed 6 August 2024).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3