Comparing iStent versus CyPass with or without phacoemulsification in patients with glaucoma: a meta-analysis

Author:

Mahdavi Fard Ali1,Patel Sangita P.2,Pourafkari Leili3,Nader Nader D.4ORCID

Affiliation:

1. Department of Ophthalmology, University at Buffalo, Buffalo, NY, USA Tabriz University of Medical Sciences, Tabriz, Iran

2. Department of Ophthalmology, Ross Eye Institute, The State University of New York at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY, USA Ophthalmology and Research Service, Veterans Administration Western New York Healthcare, System, Buffalo, NY, USA SUNY Eye Institute, Buffalo, NY, USA

3. University at Buffalo, Buffalo, NY, USA

4. Department of Anesthesiology, University at Buffalo, 77 Goodell Street, Suite #550, Buffalo, NY 14203, USA

Abstract

Bacground: The aim of this study was to conduct a meta-analysis to compare the overall intraocular pressure (IOP)-lowering effect of iStent or CyPass as isolated procedures or in combination with cataract extraction. Materials and methods: Cochrane review manager 5.3 software (RevMan® 5.3) was used for a meta-analysis of IOPs and the number of antiglaucoma medications in six groups according to the type and number of stents and whether the procedure was isolated or in combination with cataract extraction. Main results: A total of 33 out of 446 publications retrieved have been enrolled. The mean changes in IOP in the groups with one iStent and more than two iStents with concurrent cataract extraction were −3.78 ± 0.53 mmHg and −3.89 ± 0.73 mmHg, respectively. The mean differences in IOP in the groups with one iStent and more than two iStents without concurrent cataract extraction were −3.96 ± 0.25 mmHg and −7.48 ± 0.55 mmHg, respectively. The mean changes in IOP in the groups with CyPass implantation with and without concurrent cataract extraction were −4.97 ± 1.38 mmHg and −8.96 ± 0.16 mmHg, respectively. Conclusions: Both iStent and CyPass either in combination with cataract extraction or as isolated procedures effectively decrease IOP. This effect is greatest with isolated implantation of CyPass followed by multiple iStents and then single iStent implantation and lasts up to 2 years.

Publisher

SAGE Publications

Subject

Medicine (miscellaneous)

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP