Tendon-driven continuum robots with extensible sections—A model-based evaluation of path-following motions

Author:

Amanov Ernar1ORCID,Nguyen Thien-Dang1,Burgner-Kahrs Jessica12ORCID

Affiliation:

1. Laboratory of Continuum Robotics, Leibniz Universität Hannover, Germany

2. Continuum Robotics Laboratory, University of Toronto Mississauga, Canada

Abstract

Continuum robots are highly miniaturizable, exhibit non-linear shapes with several curves, and are flexible and compliant. In particular, concentric-tube and tendon-driven continuum robots can be designed on a small scale with diameters of below 10 mm. A small diameter-to-length ratio enables insertion of these robots through small entry points in order to reach hardly accessible regions by avoiding obstacles. This scenario can often be found in minimally invasive surgery and technical inspections. However, to reach the target region, a deployment along a narrow tortuous path is often required. Common tendon-driven continuum robots are intrinsically incapable of such deployment and concentric-tube continuum robots require special path conditions and intensive parameter optimization. Other proposed robot types, such as hyper-redundant and pneumatically actuated robots, exhibit less favorable diameter-to-length ratios and are thus not suitable for those tasks. Since the limiting factors are found in the design of continuum robots, we propose a novel tendon-driven continuum robot design, which features an additional degree of freedom in each robot section. The backbone is composed of straight, concentrically arranged tubes, each of which composes a section and is used to adapt its length. We present a three-section continuum robot prototype with a diameter of 7 mm, determine its follow-the-leader capabilities theoretically, and validate the results experimentally using model-based control. For our 165 mm long robot prototype, the repeatability is below 2.38 mm. The model accuracy reaches a median of 3.16% over 25 configurations with respect to robot length. The path-following error over five curvilinear paths results in median errors of 2.59% with respect to robot length.

Funder

Deutsche Forschungsgemeinschaft

Publisher

SAGE Publications

Subject

Applied Mathematics,Artificial Intelligence,Electrical and Electronic Engineering,Mechanical Engineering,Modelling and Simulation,Software

Cited by 110 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3