Application Value of Ultrasound Elastography Combined With Contrast-Enhanced Ultrasound (CEUS) Quantitative Analysis in Differentiation of Nodular Fibrocystic Changes of the Breast From Invasive Ductal Carcinoma

Author:

Li Jiajia1,Wu Yunfeng1,Tian Zhaoyu1,Shu Linfeng1,Wu Siru1,Wu Zuohui1ORCID

Affiliation:

1. Affiliated Hospital of Zunyi Medical University, Zunyi, Guizhou, China

Abstract

This study aimed to compare the value of ultrasound elastography combined with contrast-enhanced ultrasound (CEUS) quantitative analysis in the differentiation of nodular fibrocystic breast change (FBC) from breast invasive ductal carcinoma (BIDC). We selected 50 patients each with nodular FBC and BIDC, who were admitted to the Affiliated Hospital of Zunyi Medical University from January 2018 to December 2021. Their ultrasonic elastic images and CEUS videos were collected, their ultrasound elastography scores and the ratio of strain rate (SR) of the lesions were determined, and the exported DICOM format videos of CEUS were quantitatively analyzed using VueBox software to obtain quantitative perfusion parameters. The differences between the ultrasound elastography score and SR while comparing nodular FBC and BIDC cases were statistically significant ( p < .05). The sensitivity, specificity, and accuracy of ultrasound elastography scores in the differential diagnoses of nodular FBC and BIDC were 74%, 88%, and 81%, respectively. Additionally, the sensitivity, specificity, and accuracy of SR in the differential diagnosis of nodular FBC and BIDC were 94%, 78%, and 86%, respectively. Statistically significant differences were observed in the CEUS quantitative perfusion parameters PE, AUC (WiAUC, WoAUC, WiWoAUC), and WiPI in both nodular FBC and BIDC according to the VueBox software ( p < .05). The sensitivity, specificity, and accuracy of CEUS quantitative analysis in the differential diagnoses of nodular FBC and BIDC were 66%, 82%, and 74%, respectively. Using the pathological findings as the gold standard, ROC curves were established, and the area under the curve (AUC) of the CEUS quantitative analysis, elasticity score, SR, and ultrasound elastography combined with CEUS quantitative analysis were 0.731, 0.838, and 0.892, as well as 0.945, respectively. Ultrasound elasticity scoring, SR and CEUS quantitative analysis have certain application value for differentiating nodular FBC cases from BIDC; however, ultrasound elasticity imaging combined with CEUS quantitative analysis can help in improving the differential diagnostic efficacy of nodular FBC cases from BIDC.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3