Are Implant Choice and Surgical Approach Associated With Biceps Tenodesis Construct Strength? A Systematic Review and Meta-regression

Author:

Aida Hiroshi F.1,Shi Brendan Y.1,Huish Eric G.1,McFarland Edward G.1,Srikumaran Uma1

Affiliation:

1. Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD, USA

Abstract

Background: Despite the increasing use of biceps tenodesis, there is a lack of consensus regarding optimal implant choice (suture anchor vs interference screw) and implant placement (suprapectoral vs subpectoral). Purpose/Hypothesis: The purpose was to determine the associations of procedural parameters with the biomechanical performance of biceps tenodesis constructs. The authors hypothesized that ultimate failure load (UFL) would not differ between sub- and suprapectoral repairs or between interference screw and suture anchor constructs and that the number of implants and number of sutures would be positively associated with construct strength. Study Design: Meta-analysis. Methods: The authors conducted a systematic literature search for studies that measured the biomechanical performance of biceps tenodesis repairs in human cadaveric specimens. Two independent reviewers extracted data from studies that met the inclusion criteria. Meta-regression was then performed on the pooled data set. Outcome variables were UFL and mode of failure. Procedural parameters (fixation type, fixation site, implant diameter, and numbers of implants and sutures used) were included as covariates. Twenty-five biomechanical studies, representing 494 cadaveric specimens, met the inclusion criteria. Results: The use of interference screws (vs suture anchors) was associated with a mean 86 N–greater UFL (95% CI, 34-138 N; P = .002). Each additional suture used to attach the tendon to the implant was associated with a mean 53 N–greater UFL (95% CI, 24-81 N; P = .001). Multivariate analysis found no significant association between fixation site and UFL. Finally, the use of suture anchors and fewer number of sutures were both independently associated with lower odds of native tissue failure as opposed to implant pullout. Conclusion: These findings suggest that fixation with interference screws, rather than suture anchors, and the use of more sutures are associated with greater biceps tenodesis strength, as well as higher odds of native tissue failure versus implant pullout. Although constructs with suture anchors show inferior UFL compared with those with interference screws, incorporation of additional sutures may increase the strength of suture anchor constructs. Supra- and subpectoral repairs provide equivalent biomechanical strength when controlling for potential confounders.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3