Knotless Bioabsorbable Anchors Placed on the Glenoid Face for Arthroscopic Bankart Repair

Author:

Kim Su Cheol1,Kim Hyun Gon1ORCID,Na Sang Woon1,Jung Joo Sam1,Yoo Jae Chul1ORCID

Affiliation:

1. Samsung Medical Center, Seoul, Republic of Korea

Abstract

Background: Quantitative analysis of the glenoid face knotless-type anchor placement for arthroscopic Bankart repair has not been reported. Purpose: To evaluate the clinical and radiologic outcomes after arthroscopic Bankart repair using knotless bioabsorbable anchors depending on the anchor location. Study design: Case series, Level of evidence, 4. Methods: A total of 124 patients (113 men and 11 women; age, 25.6 ± 7.5 years; follow-up time, 46.5 ± 18.2 months [range, 6.2-75.5 months]) who underwent arthroscopic Bankart repair with the bioabsorbable knotless anchor between 2017 and 2021 were included in this study. Among them, 118 patients were observed for >2 years (mean, 48.2 ± 16.8 months [range, 24-75.5 months]) and were analyzed for final clinical and radiologic outcomes. Using postoperative 6-month magnetic resonance imaging, remnant glenoid (%) and labral height were measured. Shoulder range of motion (ROM), radiographic osteoarthritic change, dislocation, apprehension test, and return to sports were recorded. Three groups were established based on the remnant glenoid, which represented the percentage of the exposed glenoid anteroposterior diameter to the original diameter using the best-fit circle method—group A: lower quartile; group B: interquartile; and group C: upper quartile—and variables were analyzed. Results: Overall, the remnant glenoid was 57% ± 6.4% (range, 41.5%-75%) after the surgery. Osteoarthritic change, dislocations, and positive apprehension tests were observed in 5 (4.2%), 4 (3.4%), and 12 (10.2%) patients, respectively. A total of 34 (28.8%) and 64 (54.2%) patients could return to sports without and with restrictions, respectively. Comparing groups A, B, and C, postoperative labral height (7 ± 1, 7 ± 2, and 7 ± 1 mm; P = .623), final osteoarthritic change (1, 4, and 0; P = .440), positive apprehension tests (5, 5, and 2; P = .387), and return to sports (complete/restricted/unable, 6/18/5, 19/29/11, 9/17/4; P = .769) were not different. All ROM were similar across the groups (all P > .054), except for external rotation (ER) at postoperative 6 months (41.3°± 12.8°; 50.2°± 18.5°; and 49.8°± 15.2°; P = .050). However, ER after 1 year was similar across the groups (all P > .544). In further analysis, patients with positive apprehension tests had lower labral height compared with others (5 [4-6] mm and 7 [6-8] mm; P < .001). Conclusion: In arthroscopic Bankart repair, the placement of knotless bioabsorbable anchors on the glenoid face, combined with the remplissage procedure or rotator interval closure, resulted in a low recurrence rate and moderate return to sports. However, most patients had some restrictions in returning to sports. Moreover, this technique was not associated with postoperative arthritis and shoulder stiffness, including ER deficit, which was not affected by the position of the anchor on the glenoid face for a minimum 2-year follow-up.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3