The Long Head of the Biceps Tendon Has Minimal Effect on In Vivo Glenohumeral Kinematics

Author:

Giphart J. Erik1,Elser Florian2,Dewing Christopher B.3,Torry Michael R.4,Millett Peter J.15

Affiliation:

1. Steadman Philippon Research Institute, Vail, Colorado

2. Abteilung für Unfallchirurgie, Klinikum rechts der Isar, Technische Universität München, Munich, Germany

3. Department of Orthopaedic Surgery, Naval Medical Center San Diego, San Diego, California

4. College of Applied Science and Technology, School of Kinesiology, Illinois State University, Normal, Illinois

5. Steadman Clinic, Vail, Colorado

Abstract

Background: The in vivo stabilizing role of the long head of the biceps tendon (LHB) is poorly understood. While cadaveric studies report that the loaded LHB constrains translations in all directions, clinical data suggest that there is no clinically demonstrable alteration in glenohumeral position after LHB tenodesis or tenotomy. The purpose of this study was to investigate potential alterations in glenohumeral kinematics after LHB tenodesis during 3 dynamic in vivo motions using a biplane fluoroscopy system.Hypothesis: Our hypothesis was that there would be no difference in glenohumeral translations greater than 1.0 mm between shoulders after biceps tenodesis and healthy contralateral shoulders.Study Design: Controlled laboratory study.Methods: Five patients who underwent unilateral, open subpectoral tenodesis performed abduction, a simulated late cocking phase of a throw, and simulated lifting with both their tenodesed shoulder and their contralateral healthy shoulder inside a biplane fluoroscopy system. Dynamic 3-dimensional glenohumeral positions and electromyography activity of the biceps brachii muscle were determined and compared.Results: Significant glenohumeral translations occurred in both shoulders for abduction (3.4 mm inferiorly; P < .01) and simulated late cocking (2.6 mm anteriorly; P < .01). The mean difference for each motion in glenohumeral position between the tenodesed and the contralateral healthy shoulders was always less than 1.0 mm. The tenodesed shoulders were more anterior (centered) during abduction (0.7 mm; P < .01) and for the eccentric phase of the simulated late cocking motion (0.9 mm; P < .02). No significant differences were found during the simulated lifting motion and in the superior-inferior direction.Conclusion: The effect of biceps tenodesis on glenohumeral position during the motions studied in vivo was minimal compared with physiological translations and interpatient variability.Clinical Relevance: Our findings demonstrated that LHB tenodesis does not dramatically alter glenohumeral position during dynamic motions, suggesting the risk for clinically significant alterations in glenohumeral kinematics after tenodesis is low in otherwise intact shoulders.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3