Abstract

Twenty-seven paired human cadaveric knee specimens were used to determine the effect of surgical technique and various interference screw parameters on the pullout strength of patellar tendon femoral bone blocks. The study compared the fixation strength of endoscop ically inserted and conventional "rear-entry" screws of different diameters and lengths. In all tests the most frequent mode of failure was bone block pullout from the interference screw. There was no significant differ ence in fixation strength between 9-mm diameter screws inserted through a conventional rear-entry tech nique and 7-mm diameter screws inserted through an endoscopic technique. There was no significant effect of screw length on fixation strength. The pullout force for 20-mm long screws increased on average 120% when 7-mm diameter screws were compared with 5.5- mm diameter screws. There was no significant effect of increased screw core diameter on fixation strength. There was a weak positive correlation ( r2 = 0.45) between screw insertion torque and pullout force. Our measured mean pullout force for the 7-mm endoscopi cally inserted screws of 362 ± 198 N represents 20.1 % of the failure load of the normal young adult anterior cruciate ligament. Our data indicate that properly in serted 7-mm diameter endoscopic interference screws can provide fixation strengths of patellar tendon ante rior cruciate ligament grafts equivalent to those of con ventional 9-mm diameter rear-entry, outside-in screws.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference28 articles.

1. Acker JH, Drez D.: Analysis of isometric placement of grafts in ACL reconstruction procedures . Am J Knee Surg 2: 65-70, 1989

2. Andrews JR, Indelicato PA, Noyes FR, et al: Surgical controversies: Autografts or allografts for ACL reconstruction . Strategies for Rehabilitative Orthopaedics Biodex Professional Services 1: 2-5, 1989

3. Determination of graft tension before fixation in anterior cruciate ligament reconstruction

4. Butler DL: Evaluation of fixation methods in cruciate ligament replacement. Instr Course Lect 36: 173-178, 1987

5. Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3