Outcome and Structural Integrity after Arthroscopic Rotator Cuff Repair Using 2 Rows of Fixation

Author:

Anderson Kyle1,Boothby Michael2,Aschenbrener Daniel3,Van Holsbeeck Marnix4

Affiliation:

1. Department of Orthopaedic Surgery, William Beaumont Hospital, Royal Oak, Michigan

2. Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan

3. St Joseph Mercy-Oakland, Pontiac, Michigan

4. Department of Musculoskeletal Radiology, Henry Ford Hospital, Detroit, Michigan

Abstract

Background Although arthroscopic repairs of the rotator cuff are becoming increasingly popular, security of fixation remains a concern. Two-row repairs have been described, but clinical outcome reports have primarily involved open techniques. Hypothesis An arthroscopic repair technique that uses 2 rows of fixation produces satisfactory outcome and structural integrity by ultrasonography. Study Design Case series; Level of evidence, 4. Methods Forty-eight patients (52 shoulders) with a full-thickness, but fully reducible, rotator cuff tear who met the inclusion criteria were treated with an arthroscopic rotator cuff repair using 2 rows of suture anchors. The mean tear size was 2.47 cm (range, 1-4 cm). Patients were evaluated by subjective functional assessment (L'Insalata Shoulder Rating Questionnaire), clinical examination, including measured strength testing, and ultrasonography. Results At a mean follow-up of 30 months (minimum of 2 years), functional scores improved from a mean of 42 preoperatively to 93 postoperatively (P <. 001). Active range of motion was increased in all measured planes (P <. 001). Strength was also increased in elevation (P <. 001), external rotation (P <. 001), and internal rotation (P =. 033). Nine of the 52 shoulders (17%) had evidence of retear or persistent defect on postoperative ultrasonography. There were no differences detected in functional scores between those with an intact repair and those with a defect, but those with an intact repair were stronger in elevation (P =. 006) and external rotation (P =. 001). Conclusion An arthroscopic 2-row rotator cuff repair produces excellent functional outcome and repair integrity comparable with previously reported open repairs. Presence of a defect after repair did not appear to affect patient-reported function and return to preinjury activity but did affect measured strength.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 195 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3