Patient-Specific Distal Femoral Guides Optimize Cartilage Topography Matching in Osteochondral Allograft Transplantations

Author:

Elias Tristan J.1,Credille Kevin1,Wang Zachary1,Inoue Nozomu1,Espinoza Orías Alejandro A.1,Beals Corey T.1,Haneberg Erik1,Hevesi Mario12,Cole Brian J.1,Yanke Adam B.1

Affiliation:

1. Rush University Medical Center, Chicago, Illinois, USA

2. Mayo Clinic, Rochester, Minnesota, USA

Abstract

Background: Osteochondral allograft (OCA) transplantation is an important surgical technique for full-thickness chondral defects in the knee. For patients undergoing this procedure, topography matching between the donor and recipient sites is essential to limit premature wear of the OCA. Currently, there is no standardized process of donor and recipient graft matching. Purpose: To evaluate a novel topography matching technique for distal femoral condyle OCA transplantation using 3-dimensional (3D) laser scanning to create 3D-printed patient-specific instrumentation in a human cadaveric model. Study Design: Descriptive laboratory study. Methods: Human cadaveric distal femoral condyles (n = 12) underwent 3D laser scanning. An 18-mm circular osteochondral recipient defect was virtually created on the medial femoral condyle (MFC), and the position and orientation of the best topography-matched osteochondral graft from a paired donor lateral femoral condyle (LFC) were determined using an in silico analysis algorithm minimizing articular step-off distances between the edges of the graft and recipient defect. Distances between the entire surface of the OCA graft and the underneath surface of the MFC were evaluated as surface mismatch. Donor (LFC) and recipient (MFC) 3D-printed patient-specific guides were created based on 3D reconstructions of the scanned condyles. Through use of the guides, OCAs were harvested from the LFC and transplanted to the reamed recipient defect site (MFC). The post-OCA recipient condyles were laser scanned. The 360° articular step-off and cartilage topography mismatch were measured. Results: The mean cartilage step-off and graft surface mismatch for the in silico OCA transplant were 0.073 ± 0.029 mm (range, 0.005-0.113 mm) and 0.166 ± 0.039 mm (range, 0.120-0.243 mm), respectively. Comparatively, the cadaveric specimens postimplant had significantly larger step-off differences (0.173 ± 0.085 mm; range, 0.082-0.399 mm; P = .001) but equivalent graft surface topography matching (0.181 ± 0.080 mm; range, 0.087-0.396 mm; P = .678). All 12 OCA transplants had mean circumferential step-off differences less than a clinically significant cutoff of 0.5 mm. Conclusion: These findings suggest that the use of 3D-printed patient-specific guides for OCA transplantation has the ability to reliably optimize cartilage topography matching for LFC to MFC transplantation. This study demonstrated substantially lower step-off values compared with previous orthopaedic literature when also evaluating LFC to MFC transplantation. Using this novel technique in a model performing MFC to MFC transplantation has the potential to yield further enhanced results due to improved radii of curvature matching. Clinical Relevance: Topography-matched graft implantation for focal chondral defects of the knee in patients improves surface matching and has the potential to improve long-term outcomes. Efficient selection of the allograft also allows improved availability of the limited allograft sources.

Funder

National Institutes of Health

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3