Affiliation:
1. Division of Anaesthesia, Prince of Wales Hospital, Sydney, New South Wales
Abstract
Sore throat and hoarseness following tracheal intubation is common. The aetiology may include high tracheal cuff pressures. We performed a double-blind, randomized controlled trial in 126 intubated patients to compare the incidence and severity of sore throat and hoarseness following inflation of the cuff using air or saline. Intra-cuff pressures were compared to assess any change due to inward diffusion of nitrous oxide. The incidence of significant sore throat and/or hoarseness overall was 15.0%. There was no statistically significant difference between the groups (air 15.9%, saline 14.5%). In the air group mean intra-cuff pressure increased significantly (start 14.0 mmHg, end 40.9 mmHg), while in the saline group there was no significant increase (start 12.7 mmHg, end 14.6 mmHg). The substitution of saline reliably results in sustained low intra-cuff pressures but high tracheal cuff pressure is not an important factor in the development of sore throat or hoarseness postoperatively within the pressure range and duration of operation studied.
Subject
Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine
Cited by
40 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献