Bone Remodelling in THA: A Comparative DXA Scan Study between Conventional Implants and a New Stemless Femoral Component. A Preliminary Report

Author:

Albanese C.V.1,Rendine M.2,De Palma F.3,Impagliazzo A.4,Falez F.5,Postacchini F.6,Villani C.6,Passariello R.1,Santori F.S.2

Affiliation:

1. Unit of Osteoporosis and Musculoskeletal Disease, Department of Radiologic Science, University of Rome “La Sapienza”, Rome - Italy

2. Orthopaedic Division, San Pietro Fatebenefratelli Hospital, Rome - Italy

3. Orthopaedic Division, S. Filippo Neri Hospital, Rome - Italy

4. First Orthopaedic Division, CTO Hospital, Rome - Italy

5. Orthopaedic Division, S. Spirito Hospital, Rome - Italy

6. Department of Orthopaedic Sciences, University of Rome “La Sapienza”, Rome - Italy

Abstract

Periprosthetic bone loss is a major cause for concern in patients undergoing total hip arthroplasty (THA). There are many different factors that may determine the pattern of bone loss and bone remodelling following THA, such as the quality of the bone before the hip replacement, skeletal bone mass at the time of the operation, material and method of fixation and implant design. Recent developments in dual-energy X-ray absorptiometry (DXA) have made it possible to quantify bone mineral density (BMD) to evaluate changes around the prosthesis and to measure bone stock and bone density redistribution after a total hip replacement. In this cross-sectional multicentre clinical study the DXA method was used to compare bone mass after uncemented THA of a custom-made stemless design with five groups of conventional cementless implants (Alloclassic, Mayo, CFP, IPS, ABG). The adaptive bone changes of the proximal femur three years after implantation were evaluated. Periprosthetic BMD was measured in 130 subjects in the seven regions of interest (ROI) based on Gruen zones. Significant differences were found between the stemless implant and the other five groups in zones 1, 4 and 7. The CFP, IPS, and ABG groups showed decreased BMD in ROI 1, and the Mayo, IPS and Alloclassic in ROI 7. An increased BMD in ROI 4 was observed in the Mayo, IPS, ABG and Alloclassic groups. The results of the present study suggest that a conservative stemless implant with complete proximal load transfer produces a homogeneous and more physiological redistribution of bone density, allowing maintenance of proximal periprosthetic bone stock.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3