Comparison of Tmax values between full- and half-dose gadolinium perfusion studies

Author:

Christensen Søren1,Amukotuwa Shalini23,Lansberg Maarten G1,Kemp Stephanie1,Heit Jeremy J4ORCID,Mlynash Michael1,Marks Michael P4,Albers Greg W3,Bammer Roland5

Affiliation:

1. Stanford Stroke Center, Stanford University School of Medicine, Stanford, CA, USA

2. Diagnostic Imaging, Monash Health, Clayton, Australia

3. Department of Radiology, Barwon Health, Geelong, Australia

4. Diagnostic and Interventional Neuroradiology Department, Stanford University School of Medicine, Stanford, CA, USA

5. Department of Radiology, University of Melbourne, Parkville, Australia

Abstract

AHA guidelines recommend use of perfusion imaging for patient selection in the 6–24 h window. Recently, the safety of gadolinium-based contrast agents for MR perfusion imaging has been questioned based on findings that gadolinium accumulates in brain tissue. Regulatory bodies have recommended to limit the use of gadolinium-based contrast agents where possible. Focusing specifically on the time to maximum of the tissue residue function (Tmax) parameter, used in DAWN and DEFUSE 3, we hypothesized that half-dose scans would yield a similar Tmax delay pattern to full-dose scans. We prospectively recruited 10 acute ischemic stroke patients imaged with two perfusion scans at their follow-up visit, one with a standard dose gadolinium followed by a half-dose injection a median of 7 min apart. The brain was parcellated into a grid of 3 × 3 regions and the mean of the difference in Tmax between the 3 × 3 regions on the half- and full-dose Tmax maps was 0.1 s (iqr 0.38 s). The fraction of brain tissue that differed by no more than ±1 s was 93.7%. In patients with normal or modest Tmax delays, half-dose gadolinium appears to provide comparable Tmax measurements to those of full-dose scans.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical),Neurology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. MR perfusion imaging: Half‐dose gadolinium is half the quality;Journal of Neuroimaging;2021-05-18

2. Role of gadolinium-based contrast agents in neurological disorders;Neurologia i Neurochirurgia Polska;2020-10-30

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3