Numerical investigation of the influence of a bearing/shaft structure in an axial blood pump on the potential for device thrombosis

Author:

Liu Guang-Mao12,Jin Dong-Hai1,Chen Hai-bo2,Hou Jian-feng2,Zhang Yan2,Sun Han-song2,Zhou Jian-Ye2,Hu Sheng-shou2,Gui Xing-Min1

Affiliation:

1. School of Energy and Power Engineering, Beihang University, Beijing, China

2. State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fu Wai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China

Abstract

Adverse events caused by flow-induced thrombus formation around the bearing/shaft of an axial blood pump remain a serious problem for axial blood pumps. Moreover, excessive anticoagulation with thrombosis around the bearing potentially increases the risk of postoperative gastrointestinal bleeding. The purpose of this study is to analyze the influence of the bearing structure on the thrombosis potential of an axial blood pump. The bearing/shaft structure was embedded into an axial blood pump numerical model. The numerical simulation and analysis are focused on the low wall shear stresses, recirculation, and residence time close to the bearing region to evaluate the potential for thrombosis around the bearing. Then, the flow field near the blood pump bearing was tested via in vitro particle image velocimetry experiments to verify the numerical results. The simulation results showed that after embedding the bearing/shaft structure a recirculation zone appeared in the outlet guide vane bearing/shaft region, the residence time increased 11-fold in comparison to the pump without the bearing/shaft structure, the scalar shear stress in the shaft surface was less than 7.8 Pa, and the stress accumulation was less than 0.10 Pa s. The numerical results showed that platelets that flow through the bearing region are exposed to significantly lower wall shear stress and a longer residence time, leading to activated platelet adhesion. The reduced stress accumulation and increased time in the bearing region lead to increased platelet activation.

Funder

institute of geographic sciences and natural resources research, chinese academy of science

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3