Effect of High-Dose Drug-Coated Balloon Repetition After Drug-Coated Balloon Failure

Author:

Tomoi Yusuke1ORCID,Takahara Mitsuyoshi2,Soga Yoshimitsu1ORCID,Hirano Taichi1,Tsunoda Kazuki1,Katsuki Tomonori1ORCID,Ando Kenji1

Affiliation:

1. Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan

2. Department of Metabolic Medicine, Graduate School of Medicine, Osaka University, Suita, Japan

Abstract

Purpose: Although the optimal treatment for femoropopliteal (FP) drug-coated balloon (DCB) restenosis lesions remains debatable, the effectiveness of DCB repetition for DCB restenosis has been reported. However, the optimal DCB repetition strategy is not yet established. Thus, this study aimed to compare the clinical outcomes of high-dose DCB repetition with those of low-dose DCB repetition for FP DCB restenosis lesions. Materials and Methods: This single-center, observational study used a clinical database of 677 consecutive patients undergoing FP endovascular intervention for symptomatic peripheral artery disease between December 2018 and December 2021. Of these patients, 89 cases treated with DCB repetition for FP DCB restenosis lesions were analyzed. The primary endpoint was recurrent restenosis (re-restenosis) and the secondary endpoints were recurrent target-lesion revascularization (TLR), re-occlusion, and major adverse limb events (MALE) obtained using propensity score matching. Interaction analysis was also performed to explore the effects of the baseline characteristics on the association between high- and low-dose DCB with restenosis risk. Results: After propensity score matching, high-dose DCB demonstrated a significantly higher freedom from re-restenosis compared with low-dose DCB repetition at 1 year (90.4% vs 40.9%, p=0.034). In addition, freedom from re-TLR and MALE at 1 year was significantly higher in the high-dose DCB group (95.0% vs 53.3%, p=0.025; 95.0% vs 54.7%, p=0.025, respectively). Conversely, freedom rates from re-occlusion were not significantly different between the 2 groups (100.0% vs 84.0%, p=0.99). No baseline characteristics or perioperative outcomes had any significant interaction effect on the association of high-dose DCB versus low-dose DCB with restenosis risk. Conclusion: For FP DCB restenosis lesions, high-dose DCB repetition offered more favorable outcomes than low-dose DCB repetition. Clinical Impact This study revealed that for femoropopliteal drug-coated balloon (DCB) restenosis lesions, high-dose DCB repetition obtained more favorable outcomes than low-dose DCB repetition. In addition, there was no significant interaction effect on the association of high- versus low-dose DCB with re-restenosis risk for the baseline characteristics and perioperative outcomes. This finding might be also a reason for choosing high-dose DCB repetition for FP DCB restenosis lesions in daily clinical practice.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3