Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles

Author:

C. Schaefer Tabea12,Greive Svenja1,Heiland Sabine1,Kramer Martin2,Bendszus Martin1,Vollherbst Dominik F.1ORCID

Affiliation:

1. Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany

2. Clinic for Small Animals, Justus Liebig University Gießen, Gießen, Germany

Abstract

Background: Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a catheter on these MAB, and to demonstrate the applicability of this model in vivo. Materials and Methods: Micro air bubbles were created using a system based on microfluidic channels. The MAB were detected and analyzed automatically. Micro air bubbles, with a target size of 85 µm, were generated and injected through a microcatheter. The MAB diameters proximal and distal to the catheter were assessed and compared. In a subsequent in vivo application, 2000 MAB were injected into the aorta (at the aortic valve) and into the common carotid artery (CCA) of a rat, respectively, using a microcatheter, resembling AE occurring during cardiovascular interventions. Results: Micro air bubbles with a highly calibrated size could be successfully generated (median: 85.5 µm, SD 1.9 µm). After passage of the microcatheter, the MAB were similar in diameter (median: 86.6 µm) but at a lower number (60.1% of the injected MAB) and a substantially higher scattering of diameters (SD 29.6 µm). In vivo injection of MAB into the aorta resulted in cerebral microinfarctions in both hemispheres, whereas injection into the CCA caused exclusively ipsilateral microinfarctions. Conclusion: Using this new AE model, MAB can be generated precisely and reproducibly, resulting in cerebral microinfarctions. This model is feasible for further studies on the pathophysiology and prevention of AE in cardiovascular procedures.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Reference34 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Iatrogenic air embolism: influence of air bubble size on cerebral infarctions in an experimental in vivo and numerical simulation model;Journal of NeuroInterventional Surgery;2023-09-06

2. Modell zur Erzeugung von Mikroluftbläschen bei Luftembolien;Gefäßmedizin Scan - Zeitschrift für Angiologie, Gefäßchirurgie, diagnostische und interventionelle Radiologie;2022-11-21