Evaluation of Quiescent-Interval Single-Shot Magnetic Resonance Angiography in Diabetic Patients With Critical Limb Ischemia Undergoing Digital Subtraction Angiography: Comparison With Contrast-Enhanced Magnetic Resonance Angiography With Calf Compression at 3.0 Tesla

Author:

Wei Li-Ming1,Zhu Yue-Qi1,Zhang Pei-Lei1,Lu Hai-Tao1,Zhao Jun-Gong1ORCID

Affiliation:

1. Department of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai, China

Abstract

Purpose: To assess the diagnostic performance of quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) at 3 tesla in diabetic patients with critical limb ischemia (CLI) vs contrast-enhanced MR angiography (CE-MRA) using digital subtraction angiography (DSA) as the standard of reference. Method: Thirty-seven consecutive diabetic patients (mean age 71.8±7.2 years; 30 men) with CLI (Fontaine stage III–IV) underwent QISS-MRA and CE-MRA with calf compression; DSA was the standard. Image quality (5-point Likert-type scale) and stenosis severity (5-point grading) for QISS-MRA and CE-MRA were evaluated by 2 blinded readers in 1147 and 654 vessel segments, respectively. Per-segment and per-region (pelvis, thigh, calf) sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Results: Image quality of QISS-MRA was lower compared with CE-MRA in the pelvic region (p<0.001 in both readers) and thigh region (p=0.033 in reader 1 and p=0.018 in reader 2), whereas in the calf region, the image quality of QISS-MRA was better than CE-MRA (p=0.009 in reader 1 and p=0.001 in reader 2). In segment-based analyses, there was no difference between QISS-MRA and CE-MRA in sensitivity [89.5% vs 90.3% in reader 1 (p=0.774) and 87.6% vs 90.6% in reader 2 (p=0.266)] or specificity [94.2% vs 92.9% in reader 1 (p=0.513) and 92.9% vs 92.9% in reader 2 (p>0.999)]. In region-based analyses, QISS-MRA and CE-MRA yielded similar sensitivity and specificity in all areas but the pelvic region for reader 2 (specificity 95.5% vs 84.8%, p=0.041). Conclusion: QISS-MRA performed very well in diabetic patients with CLI and was a good alternative for patients with contraindications to CE-MRA.

Funder

Shanghai key discipline of medical imaging

Science Foundation of Shanghai Jiao Tong University Affiliated Sixth People’s Hospital

the National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3