The Elevator Technique: A New Bailout Maneuver to Achieve Target Vessel Patency During Challenging BEVAR

Author:

Lerisson Erol1ORCID,Le Houérou Thomas1,Rockley Mark1,Gaudin Antoine1,Costanzo Alessandro1,Fabre Dominique1,Haulon Stéphan1

Affiliation:

1. Aortic Center, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint-Joseph, Paris Saclay University, Paris, France

Abstract

Purpose: The purpose of the study is to describe a new bailout maneuver for use during branched endovascular thoracoabdominal aneurysm repair (BEVAR) while dealing with challenging target vessel cannulation. Technique: A 54-year-old woman underwent urgent BEVAR with a low-profile T-branch device to exclude a type 2 thoracoabdominal aneurysm (TAAA). The endovascular procedure was challenging because the left renal artery ostium was covered by the endograft fabric, compounded by diseased target vessels. A novel bailout maneuver is described. After angioplasty of the left renal artery (LRA), the LRA remained precannulated and a low-profile T-branch was implanted. The 3 proximal branches (superior mesenteric artery, inferior mesenteric artery, and the right renal artery) were connected to their respective target vessels swiftly with a steerable sheath from a femoral approach. Access to the left renal artery was not achieved because it was obstructed by the fully deployed endograft. We subsequently stented the LRA over the “pre-positioned buddy wire,” using a balloon-expandable covered stent protruding inside the aneurysm lumen. The proximal stent was then flared and lifted upward using an 8.5 Fr steerable sheath, which made cannulation and stenting of the LRA through the side-branch from above finally achievable. Conclusion: The elevator technique described in this article will help achieve technical success in challenging BEVAR cases. Clinical Impact We describe in this technical note the “elevator technique” that will complement the “Snare-Ride” and “Balloon Anchoring” techniques over a buddy wire positioned in a target vessel, to provide successful bailout options for challenging TV cannulations during BEVAR.After failed access to the renal artery through the renal branch, a covered stent was implanted in the renal artery over the buddy wire with 10 mm protruding into the aortic lumen. This stent was then flared, prior to advancing a curved steerable sheath into the stent, which shaped it with a superior-facing funneled aortic segment. This maneuver resulted in the renal stent facing its corresponding branch, finally easy to access from the endograft lumen.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3