FreeStyle Lite—A Blood Glucose Meter That Requires No Coding

Author:

Alva Shridhara1

Affiliation:

1. Abbott Diabetes Care, Alameda, California

Abstract

Background: Abbott Diabetes Care introduced the FreeStyle® Lite blood glucose monitoring system, which simplifies the management of diabetes. The FreeStyle Lite system relies on FreeStyle technology but eliminates the need for coding the meter for individual strip lots. The meter is precoded for the FreeStyle Lite strips. FreeStyle systems use coulometry technology where the glucose signal is calculated from the total charge generated as a result of the glucose reaction in the sample. FreeStyle strip calibration parameters can be controlled by controlling the sample volume. Coulometry technology is less sensitive to measurement conditions such as temperature and hematocrit. FreeStyle chemistry is less sensitive to interference from electroactive compounds. The ability to control calibration parameters coupled to a robust measurement technology enabled the development of a blood glucose monitoring system that does not require coding by the user. Methods: Laboratory studies were performed to determine analytical performance, such as linearity, precision, and sensitivity to operating temperature. Clinical accuracy for finger tip capillary blood testing was assessed with five lots of FreeStyle Lite test strips. FreeStyle Lite results in these studies were compared to the plasma equivalent glucose values of finger tip blood samples measured by the Yellow Springs Instrument glucose analyzer. Results: In the analytical performance evaluation, repeatability (within-run precision) of the FreeStyle Lite system showed an average standard deviation of 3.4 mg/dl (0.19 mmol/liter) at glucose concentrations <100 mg/dl (<5.56 mmol/liter) and an average coefficient of variation of 4.3% at glucose concentrations ≥100 mg/dl (≥5.56 mmol/liter). Linearity demonstrated across the measuring range of the FreeStyle Lite system was 20–500 mg/dl (1.1–27.8 mmol/liter) with r2 > 0.99. The FreeStyle Lite system was also shown to maintain accuracy across the operating temperature range of 4 to 40°C. Conclusions: The FreeStyle Lite system has good analytical performance and clinical accuracy. While simplifying the process of blood glucose monitoring, the FreeStyle Lite system continues to provide the performance that users have come to expect from FreeStyle products.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3