Contrast media volume is significantly related to patient lung volume during CT pulmonary angiography when employing a patient-specific contrast protocol

Author:

Saade CharbelORCID,Ghosn YoussefORCID,Alfout Ghina,Mahmoud Mustafa Zuhair,Rawashdeh Mohammad Ahmmad,Karout Lina,Ghieh Diamond,El-Merhi Fadi

Abstract

Aim: The purpose of this study is to investigate the relationship between contrast media volume and patient lung volume when employing a patient-specific contrast media formula during pulmonary computed tomography angiography (CTA). Materials and methods: IRB approved this retrospective study. CTA of the pulmonary arteries was performed on 200 patients with suspected pulmonary embolism (PE). The contrast media volume (CMV) was calculted by employing a patient-specific contrast formula. Lung volume was quantified employing semi-automated lung software that calculated lung volumes (intellispace -Philips). The mean cross-sectional opacification profile of central and peripheral pulmonary arteries and veins were measured for each patient and arteriovenous contrast ratio (AVCR) calculated for each lung segment.  Mean body mass index (BMI) and lung volume were quantified. Receiver operating (ROC) and visual grading characteristics (VGC) measured reader confidence in emboli detection and image quality respectively. Inter and intra-observer variations were investigated employing Cohen’s kappa methodology. Results: Results showed that the mean pulmonary arterial opacification of the main pulmonary circulation (343.88±73HU), right lung; upper (316.51±23HU), middle (312.5±39HU) and lower (315.23±65HU) lobes and left; upper (318.76±83HU), and lower (321.91±12HU) lobes. The mean venous opacification of all pulmonary veins was below 182±72HU. AVCR was observed at all anatomic locations (p<0.0002) where this ratio was calculated. Moreover, larger volumes of contrast significantly correlated with larger lung volumes (r=0.89, p<0.03) and radiation dose (p<0.03). VGC and ROC analysis demonstrated increased area under the curve: 0.831 and 0.99 respectively (p<0.02). Inter-observer variation was observed as excellent (κ = 0.71). Conclusion: We conclude that increased CMV is significantly correlated to increased patient lung volume and radiation dose when employing a patient-specific contrast formula. The effects patient habitus is highlighted.

Publisher

Scientific Scholar

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3