Influence of moderate prosthesis–patient mismatch on long-term outcomes in patients with severe aortic stenosis with paradoxically reduced gradients against the background of reduced stroke volume after aortic valve replacement with a biological prosthesis: retrospective comparative study

Author:

Bazylev Vladlen V.ORCID,Babukov Ruslan M.ORCID,Bartosh Fedor L.ORCID,Levina Alena V.ORCID

Abstract

OBJECTIVE: Our aim was to evaluate the impact of moderate prosthesis–patient mismatch on long-term results after aortic valve replacement in patients with severe aortic stenosis with paradoxically reduced gradients against the background of a reduced stroke volume of the left ventricle. MATERIALS AND METHODS: We analyzed data from 88 patients with symptomatic severe aortic stenosis meeting the criteria: paradoxically reduced gradients against the background of a reduced stroke volume of the left ventricle. Patients were divided into 2 groups: Group 1 (n=42, mean age 67±4 years) with paradoxically reduced gradients against the background of reduced stroke volume of the left ventricle, with a moderate patient–prosthesis mismatch; Group 2 (n=46, mean age 68±6 years) with paradoxically reduced gradients against the background of reduced stroke volume of the left ventricle, without patient–prosthesis discrepancy. All patients underwent transthoracic echocardiographic evaluation. RESULTS: The average follow-up period was 84 (quarterly interval 75±98) months, during the follow-up period 35 (40%) deaths were registered. There were no significant differences in in-hospital mortality: 2 (4.7%) and 2 (4.3%), respectively (p=0.2). In the long-term follow-up period, there was a significant difference in survival and hospitalization rates for exacerbation of heart failure between patients with and without patient–prosthesis mismatch: 46 and 71%, 37 and 72%, respectively (p0.001). In the long-term follow-up period, patients with patient–prosthesis mismatch showed a trend towards slower regression of left ventricle mass and left atrial volume, as well as a slower recovery of global longitudinal deformation of the left ventricle and exercise tolerance compared with patients without patient–prosthesis mismatch. There were no significant differences in the incidence of stroke (90% and 91%; p=0.7). According to the results of Cox regression, the left ventricular stroke volume index and the aortic valve effective orifice area index were independent predictors of lethal events and the risk of hospitalization for exacerbation of heart failure. CONCLUSION: Moderate patient–prosthesis mismatch in patients with paradoxically reduced gradients associated with reduced left ventricular stroke volume is independently associated with increased mortality and increased hospitalization for exacerbations of heart failure.

Publisher

ECO-Vector LLC

Subject

Cardiology and Cardiovascular Medicine,Rehabilitation,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3