Assessment of articulation parameters settings repeatability in Avantis 3D software

Author:

Kovgan Dmitry S.1ORCID,Erokhin Vladislav A.2ORCID,Antonik Pavel M.3ORCID,Antonik Mikhail M.3ORCID,Saveliev Vasiliy V.1ORCID,Parunov Vasiliy A.1ORCID,Oganesyan Artak S.4ORCID

Affiliation:

1. Peoples’ Friendship University of Russia named after Patrice Lumumba

2. Samara State Medical University

3. Russian University of Medicine

4. Academician I.P. Pavlov First St. Petersburg State Medical University

Abstract

BACKGROUND: The three-dimensional (3D) space of a virtual articulator requires precise adjustment considering individual parameters for the precision work of orthopedic dentists, orthodontists, and dental technicians. A modern solution that includes a virtual articulator is the domestic Avantis 3D software, which simplifies and speeds up functional diagnostics by creating a 3D scene of the patient. AIM: To compare a repeatability of articulation parameters obtained when adjusting the domestic virtual articulator Avantis 3D using laboratory and intraoral scans of terminal positions of the lower jaw. MATERIALS AND METHODS: A group of 30 volunteers aged 18–35 years participated in this study. The group consisted of 18 women and 12 men. Each participant underwent a computed tomography of the maxillofacial region, including the temporomandibular joint region in a state of habitual occlusion; one-stage A-silicone impressions were obtained, plaster models were cast, and silicone bite registers of three terminal positions were made. An intraoral scan of the upper and lower jaws was performed, and optical bite scans were obtained in the position of maximum fissure-tubercle contact and in the terminal positions of the lower jaw, fixed by previously obtained silicone registers. The same protocol was conducted for plaster models of the patient’s dentition and silicone registers of terminal positions. Using intraoral scans, optical recorders of terminal positions and computer tomograms in the Avantis 3D program and 3D scenes were created, and a virtual articulator was configured. For each patient, the virtual articulator was adjusted in the Avantis 3D software, seven times using data from the intraoral scanner level and seven times from the laboratory level. The reproducibility of articulatory parameters was assessed for all types of scans obtained, examining the standard and individual intercondylar distances for each patient. RESULTS: The average values of the standard square deviation of articulatory parameters obtained when creating 3D scenes using laboratory scans at individual and standard intercondylar distances were higher than the similar values obtained using intraoral scans. CONCLUSION: The accuracy of creating a virtual copy of a patient can be influenced by several factors: the error in combining scans, repeated scanning, the error in combining scans and computer tomograms, the error in combining jaw and bite scans, and the presence of penetrating occlusal contacts between scans of the dentition.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3