Resting Hemodynamics and Response to Exercise Using the 6-Minute Walk Test in Late Pregnancy: An International Prospective Multicentre Study

Author:

Dennis Alicia Therese12,Salman Marwa3,Paxton Emma1,Flint Margot456,Leeton Liz1,Roodt Francois456,Yentis Steve78,Dyer Robert Anthony456

Affiliation:

1. Department of Anaesthesia, Royal Women’s Hospital, Parkville, Australia

2. Departments of Pharmacology, Obstetrics and Gynaecology, and Medicine and Radiology, The University of Melbourne, Parkville, Australia

3. Department of Anaesthesia, Guy’s & St Thomas’ Hospital, Lambeth, United Kingdom

4. Groote Schuur Hospital, Cape Town, South Africa

5. Mowbray Maternity Hospital, Cape Town, South Africa

6. Department of Anaesthesia and Perioperative Medicine, University of Cape Town, Cape Town, South Africa.

7. Department of Anaesthesia, Chelsea and Westminster Hospital, London, United Kingdom

8. Imperial College London, London, United Kingdom

Abstract

BACKGROUND: Cardiac disease is the leading cause of maternal death. Assessment of cardiovascular fitness is important in pregnant women because it is linked to increased risk of cardiac disease but is rarely undertaken or studied. The 6-Minute Walk Test (6MWT) is a safe exercise test but is not used in pregnancy. We determined the 95% reference interval for resting heart rate (HR) and distance walked for the 6MWT, as well as hemodynamic recovery variables, and quantified expectations and actual experiences of exertion and breathlessness with exercise in late pregnancy. METHODS: After institutional research board approval (Australian and New Zealand Clinical Trials Registry Number: 12615000964516), 300 healthy term nulliparous pregnant women performed the 6MWT at 3 tertiary referral obstetric hospitals using a standardized protocol. Each woman underwent two 6MWT with maximum 15-minute recovery period after each test. Hemodynamic variables were measured at rest and after exercise. Participants were asked 4 questions, 2 regarding expectation and 2 regarding actual experience, using the Rating of Perceived Exertion scale and Modified Borg Dyspnea scale. RESULTS: Participant characteristics and resting variables were mean (standard deviation [SD]); age, 31 years (4.2 years); body mass index, 27 kg/m2 (2.9 kg/m2); gestational age, 37 weeks (1.3 weeks); HR, 85 bpm (10.8 bpm) with 95% reference interval 64–106 bpm; systolic blood pressure, 112 mm Hg (10.2 mm Hg); diastolic blood pressure, 72 mm Hg (8.6 mm Hg); oxygen saturation, 98% (0.9%); and respiratory rate, 18 breaths/min (5.7 breaths/min). The mean (SD) average distance walked was 488 m (94.9 m) with a speed of 3.0 mph (0.64 mph) with a 95% reference interval of 302–674 m. The mean (SD) HR increase with exercise was 12 bpm (11.0 bpm) with a median [quartile] recovery time of 5.0 minutes [1–8 minutes]. A lower resting HR was associated with increased distance walked (r = −0.207; 95% confidence interval, −0.313 to −0.096; P < .001). A greater HR change with exercise was associated with increased recovery time from exercise (r = 0.736; 95% confidence interval, 0.697–0.784; P < .001). Sixty-three percent and 83% of participants, respectively, expected to be more exerted and breathless than they actually were with exercise. CONCLUSIONS: The 6MWT is feasible and applicable in term pregnant women. The reference intervals for resting HR and distance walked in the 6MWT have been generated. HR increases by approximately 12 bpm with submaximal exercise, and half of the women recovered within 5 minutes of submaximal exercise. Women expected to be more exerted and breathless than they actually were with exercise.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3