Simulation of an HDR “Boost” with Stereotactic Proton versus Photon Therapy in Prostate Cancer: A Dosimetric Feasibility Study

Author:

Remick Jill S.1,Sabouri Pouya2,Zhu Mingyao23,Bentzen Søren M.2,Sun Kai2,Kwok Young2,Kaiser Adeel24

Affiliation:

1. Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, MD, USA

2. Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA

3. Department of Radiation Oncology, Emory University, Atlanta, GA, USA

4. Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, USA

Abstract

Abstract Purpose/Objectives To compare the dose escalation potential of stereotactic body proton therapy (SBPT) versus stereotactic body photon therapy (SBXT) using high-dose rate prostate brachytherapy (HDR-B) dose-prescription metrics. Patients and Methods Twenty-five patients previously treated with radiation for prostate cancer were identified and stratified by prostate size (≤ 50cc; n = 13, > 50cc; n = 12). Initial CT simulation scans were re-planned using SBXT and SBPT modalities using a prescription dose of 19Gy in 2 fractions. Target coverage goals were designed to mimic the dose distributions of HDR-B and maximized to the upper limit constraint for the rectum and urethra. Dosimetric parameters between SBPT and SBXT were compared using the signed-rank test and again after stratification for prostate size (≤ 50cm3 and >50cm3) using the Wilcoxon rank test. Results Prostate volume receiving 100% of the dose (V100) was significantly greater for SBXT (99%) versus SBPT (96%) (P ≤ 0.01), whereas the median V125 (82% vs. 73%, P < 0.01) and V200 (12% vs. 2%, P < 0.01) was significantly greater for SBPT compared to SBXT. Median V150 was 49% for both cohorts (P = 0.92). V125 and V200 were significantly correlated with prostate size. For prostates > 50cm3, V200 was significantly greater with SBPT compared to SBXT (14.5% vs. 1%, P = 0.005), but not for prostates 50cm3 (9% vs 4%, P = 0.11). Median dose to 2cm3 of the bladder neck was significantly lower with SBPT versus SBXT (9.6 Gy vs. 14 Gy, P < 0.01). Conclusion SBPT and SBXT can be used to simulate an HDR-B boost for locally advanced prostate cancer. SBPT demonstrated greater dose escalation potential than SBXT. These results are relevant for future trial design, particularly in patients with high risk prostate cancer who are not amenable to brachytherapy.

Publisher

International Journal of Particle Therapy

Subject

Radiology, Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3