Electrochemical Sensor Based on CuO Nanoparticles-Modified Graphite Electrode for the Detection of Malachite Green

Author:

Dasgupta Samhita1ORCID,Nag Shreya12ORCID,Das Debangana13ORCID,Roy Runu Banerjee1ORCID,Das Deepak Kumar4ORCID,Pramanik Panchanan4ORCID,Bandyopadhyay Rajib1ORCID,Tudu Bipan1ORCID

Affiliation:

1. Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata 700106, West Bengal, India

2. Department of Electrical and Computer Engineering, University of Engineering and Management, Kolkata, West Bengal, India

3. Department of Electronics and Communication Engineering, Silicon Institute of Technology, Bhubaneshwar, Odisha 751024, India

4. Department of Chemistry and Nanoscience, GLA University, Mathura, Uttar Pradesh, India

Abstract

In this study, the development of a graphite paste electrode (GPE) modified by copper oxide nanoparticles (CuO@GP) to be used as a practical and economical sensor for the electrochemical sensing of malachite green (MG) has been elucidated. The sol–gel technique was applied for the synthesis of CuO nanoparticles (NPS) from copper chloride (CuCl[Formula: see text], where the surfactant cetylpyridinium chloride (C[Formula: see text]H[Formula: see text]NCl) played the role of a capping agent. The synthesized CuO NPS were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). A bare GPE was modified using these CuO NPS and thus developed; the new electrode was used as a working electrode (WE) in a 3-electrode system for studying the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) responses of MG. Phosphate buffered saline (PBS) with a pH value of 6 was used as the optimum buffer. Using DPV, a widely linear operational range of 1–1000 [Formula: see text]M was obtained with a detection limit of 0.18 [Formula: see text]M. This CuO@GP provided excellent repeatability, reproducibility and prolonged stability for the MG molecule. For the selectivity study, various common interfering agents were used to observe MG’s corresponding peak current variation. Moreover, this electrode demonstrated a successful application for detecting MG in pond water and fish flesh. This method is effective for similar other applications.

Publisher

World Scientific Pub Co Pte Ltd

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3