Doppler twinkling artifact: physical mechanisms and place in diagnostic practice. State of the art

Author:

Gromov A. I.1ORCID,Sapozhnikov O. A.2ORCID,Kaprin A. D.3ORCID

Affiliation:

1. N. Lopatkin Scientific Research Institute of Urology and Interventional Radiology – branch of the National Medical Research Radiologiсal Center of the Ministry of Health of Russian Federation; A.I. Evdokimov Moscow State University of Medicine and Dentistry of the Ministry of Healthcare of the Russian Federation

2. Lomonosov Moscow State University; Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington

3. National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation; P. Hertsen Moscow oncology research institute – Branch of National Medical Research Radiological Centre of the Ministry of Healthcare of the Russian Federation; The Peoples' Friendship University of Russia

Abstract

The twinkling artifact has been known to specialists in ultrasound diagnostics since 1996. However, until now there is no understanding of the reasons for its appearance, and the place of its application in diagnostics.Material and methods. Electronic databases (PubMed, E-library, Web of Science) were searched studies using the keyword – “twinkling artifact”. The scientific publications on the Doppler twinkling artifact from the moment of the first reports about its existence is systematized and analyzed. The authors' own developments on this topic are presented. Modern views on this phenomenon and its place in ultrasound diagnostics are described. An explanation of the physical mechanisms of this phenomenon is given.Results. Recommendations are formulated for practitioners on changing the settings of an ultrasound scanner in order to increase twinkling artifact detectability. The directions of using the artifact to obtain additional diagnostic signs of pathological changes, which currently include the diagnosis of nephro-, uretero- and choledocholithiasis, are determined.Conclusions. The high efficiency of the use of the twinkling artifact for the diagnosis of small kidney stones, comparable with the capabilities of computed tomography, has been shown.  

Publisher

Vidar, Ltd.

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3