An aortic hemodynamic fingerprint reduced order modeling analysis reveals traits associated with vascular disease in a medical biobank

Author:

Sokolow Ryan,Kissas Georgios,Beeche Cameron,Swago Sophia,Thompson Elizabeth W.,Viswanadha Mukund,Chirinos Julio,Damrauer Scott,Perdakaris Paris,Rader Daniel J.ORCID,Witschey Walter R.ORCID

Abstract

AbstractPurposeTo determine the clinical relevance of reduced order model (ROM) aortic hemodynamic imaging-derived phenotypes (IDPs) for a range of flow conditions applied to computed tomography (CT) scan data in the Penn Medicine Biobank (PMBB).MethodsThe human thoracic aorta was automatically segmented in 3,204 chest CT scans from patients in the Penn Medicine Biobank (PMBB) patients using deep learning. Thoracic aorta anatomic IDPs such as aortic diameter and length were computed. Resistance, and flow boundary conditions, were varied, resulting in 125,000 ROM simulations, producing a fingerprint of aortic hemodynamics IDPs for a range of flow conditions. To determine the clinical relevance of the aortic hemodynamic fingerprint, untargeted phenome wide association studies (PheWAS) for disease conditions were performed using aortic geometries and pulse pressure as IDPs.ResultsBy utilizing patient metadata from the PMBB, the human aortic radius for different age groups over a normalized radius was visualized, showing how the vessel deforms with age, as well as other characteristic geometric information. The average radius of the ascending thoracic aortic data set was 26.6 ± 3.1 mm, with an average length of 310 ± 37 mm. A combination of pathology codes (phecodes) and hemodynamic simulations were utilized to develop a relationship between them, showing a strong relationship between the resulting pulse pressure and diseases relating to aortic aneurysms and heart valve disorders. The average pulse pressure calculated by the model was 22.5 ± 8.5 mmHg, with the maximum pressure modeled by the system being 201 mmHg, with the minimum being 63.6 mmHg. The pulse pressures of the most significant phecodes were examined for patients with and without the condition, showing a slight separation between the two cases. The pulse pressure was also slightly negatively correlated with the calculated tapering angle of the ascending thoracic aorta.ConclusionsROM hemodynamic simulations can be applied to aortic imaging traits from thoracic imaging data in a medical biobank. The derived hemodynamic fingerprint, describing the response of the aorta to a range of flow conditions, shows clinically relevant associations with disease.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3