Comparative evaluation of glomerular morphometric techniques reveals differential technical artefacts between FSGS and normal glomeruli

Author:

Basgen John MORCID,Reghuvaran Anand CORCID,Lin QishengORCID,Banu KhadijaORCID,Shi Hongmei,Pell John,DiRito JennaORCID,Tietjen Gregory TORCID,Perincheri SudhirORCID,Moledina Dennis GORCID,Wilson Francis PerryORCID,Menon Madhav CORCID

Abstract

AbstractMorphometric estimates of mean glomerular volume (MGV) have clinical implications, over and above histologic data. However, MGV estimation is time-consuming, could waste tissue sections and requires expertise limiting its utility in retrospective clinical studies.MethodsWe evaluated MGV using both plastic and paraffin-embedded tissue from control and FSGS mice (n=10 each) using the gold-standard Disector/Cavalieri technique (Vglom-Cav) and other reported techniques [2- or 3-profile technique, Weibel-Gomez method (W-G)]. Within Vglom-Cav we examined the precision of MGV estimation while using MGVs obtained from 5- or 10-individual glomeruli measurements vs the true mean (20 glomeruli).ResultsIn both FSGS and controls, we identified an acceptable precision of 10-glomerular sampling vs true MGV within Vglom-Cav technique [88 (79-94) % of MGV obtained were within 10% of the true MGV]. The 5-glomerular sampling was less precise [70 (56, 81) % of MGV obtained were within 10% of true MGV]. In plastic based techniques, 2- or 3-profile MGVs showed greater concordance with Vglom-Cav, than W-G MGV. The new 3-profile technique offered incremental benefit to the existing 2-profile method (improved Lin’s concordance in control and FSGS animals). We observed a consistent reduction of Vglom values within control animals (52+/-0.06%) in paraffin-embedded tissue (vs corresponding methods in plastic) demonstrating a clear shrinkage artefact due to tissue processing. FSGS glomeruli showed significantly less and more variable shrinkage artefact likely due to glomerular fibrosis.ConclusionWe report the precision of 5- or 10-glomerular sampling for MGV estimation using controls and FSGS animals. We demonstrate and quantify the shrinkage bias in MGV during tissue processing for paraffin-embedding that also differentiated control animals and FSGS. Our findings have implications for experimental studies using glomerular morphometry.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3