At-home validation of remote breathing monitoring: A proof-of-concept for long-term care of respiratory patients using a non-contact, radar-based biomotion sensor

Author:

Fischer TobitORCID,Eggert Torsten,Wildenauer Alina,Dietz-Terjung Sarah,Voisard Rainer,Schöbel Christoph

Abstract

ABSTRACTPurposeLong-term monitoring of respiratory rate (RR) is promising for the management of chronic conditions. Research interest is particularly high in chronic respiratory diseases (CRDs), especially for predicting acute exacerbations of COPD (AECOPD). The aim of the present study was to evaluate the long-term validity of a recent non-contact biomotion sensor in the home environment of CRD patients with domiciliary ventilator support, focusing on patient acceptance and usability of this device, as well as RR fluctuations related to AECOPD.Patients and methodsIn this prospective proof-of-concept study, 19 patients requiring non-invasive ventilation (NIV) and seven patients requiring invasive mechanical ventilation (IMV) were provided with the non-contact device for six and one month, respectively. Main indication for NIV therapy was COPD. Real-world validation of the device was performed by comparing nocturnal RR values between the non-contact system and both types of ventilators. The acceptance and operability of the biomotion sensor were evaluated using a questionnaire. COPD exacerbations that occurred during the study period were assessed for possible RR fluctuations preceding these events.ResultsMean absolute error (MAE) of median RR between the NIV device and the non-contact system, based on 2326 nights, was 0.78 (SD: 1.96) breaths per minute (brpm). MAE between the IMV device and the non-contact system was 0.12 brpm (SD: 0.52) for 215 nights. The non-contact device was accepted by the patients and proved to be easy to use. In some of the overall 13 cases of AECOPD, RR time courses showed variations of increased nocturnal respiratory activity a few days before the occurrence of such events.ConclusionThe present non-contact system is suitable and well accepted for valid long-term monitoring of nocturnal RR in the patient’s home environment. This finding may serve as a starting point for larger studies, e.g., to develop robust AECOPD prediction rules.KEY MASSAGESWhat is already known on this topicTechnological advances offer new possibilities for remote respiratory rate (RR) monitoring for various use cases. Although novel devices are regularly validated in an experimental environment, the often-recommended verification of this validity in long-term use, including an assessment of patient adherence, is lacking.What this study addsOne of the main challenges is the absence of a feasible reference standard for long-term RR measurement. The present work demonstrates a new approach to validate a non-contact device in the home environment by comparing RR measurements with built-in software data in a cohort of ventilator-dependent patients.How this study might affect research, practice or policyPatient compliance, difficulties, as well as their needs and requirements for such long-term monitoring were recorded in order to improve further patient-centered studies. Following this premise, we aim to encourage the development of suitable validation standards, as long-term RR monitoring could finally become viable.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3