A Retrospective Study of Factors Contributing to the Performance of an Interferon-Gamma Release Assay Blood Test for Tuberculosis Infection

Author:

Song Junhyup1ORCID,Kim Sinyoung1ORCID,Park Younhee1ORCID

Affiliation:

1. Department of Laboratory Medicine, Severance Hospital, Yonsei University College of Medicine , Seoul 03722 , Republic of Korea

Abstract

Abstract Background Tuberculosis (TB) remains a significant global health concern. Accurate detection of latent TB infection is crucial for effective control and prevention. We aimed to assess the performance of an interferon-gamma release assay blood test (QuantiFERON-TB Gold Plus [QFT-Plus]) in various clinical contexts and identify conditions that affect its results. Methods We conducted a retrospective analysis of 31 000 QFT-Plus samples collected from 26 000 subjects at a tertiary hospital in South Korea over a 4-year period and compared the rates of positivity and indeterminate results across diverse clinical situations. We also analysed the contribution of the QuantiFERON TB2 tube to the test’s sensitivity and determined optimal cutoff values for 3 hematologic parameters to distinguish false-negative results. These cutoff values were validated in a separate cohort of subjects with microbiologically confirmed subclinical TB. Results Rates of QFT-Plus positivity and indeterminate results were disparate across diagnoses. The TB2 tube increased QFT-Plus sensitivity by 4.1% (95% CI, 1.1%–7.0%) in patients with subclinical TB. Absolute lymphocyte count ≤1.19 × 109/L, absolute neutrophil count ≥5.88 × 109/L, and neutrophil-to-lymphocyte ratio ≥4.33 were effective criteria to discriminate false-negative QFT-Plus results. Application of the hematologic criteria, individually or combined with mitogen response <10 IU/mL, substantially improved performance in the main study cohort and the validation cohort. Conclusions These findings highlight the influence of clinical context and patient hematologic profiles on QFT-Plus results. To minimise neglected latent TB infections due to false-negative QFT-Plus results, serial retesting is advisable in patients with severe lymphopenia or neutrophilia, particularly when the mitogen response is <10 IU/mL.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3