Rapid Detection of SARS-CoV-2 by Low Volume Real-Time Single Tube Reverse Transcription Recombinase Polymerase Amplification Using an Exo Probe with an Internally Linked Quencher (Exo-IQ)

Author:

Behrmann Ole1,Bachmann Iris1,Spiegel Martin12,Schramm Marina1,Abd El Wahed Ahmed34,Dobler Gerhard5,Dame Gregory16,Hufert Frank T16

Affiliation:

1. Institute of Microbiology and Virology, Brandenburg Medical School Fontane, Neuruppin, Germany

2. Infection Biology Unit, German Primate Center–Leibniz Institute for Primate Research, Göttingen, Germany

3. Division of Microbiology and Animal Hygiene, University of Göttingen, Germany

4. Institute of Animal Hygiene and Veterinary Public Health, University of Leipzig, Leipzig, Germany

5. Bundeswehr Institute of Microbiology (IMB), Munich, Germany

6. Faculty of Health Sciences, Joint Faculty of the Brandenburg University of Technology Cottbus – Senftenberg, the Brandenburg Medical School Theodor Fontane and the University of Potsdam, Potsdam, Germany

Abstract

Abstract Background The current outbreak of SARS-CoV-2 has spread to almost every country with more than 5 million confirmed cases and over 300,000 deaths as of May 26, 2020. Rapid first-line testing protocols are needed for outbreak control and surveillance. Methods We used computational and manual designs to generate a suitable set of reverse transcription recombinase polymerase amplification (RT-RPA) primer and exonuclease probe, internally quenched (exo-IQ), sequences targeting the SARS-CoV-2 N gene. RT-RPA sensitivity was determined by amplification of in vitro transcribed RNA standards. Assay selectivity was demonstrated with a selectivity panel of 32 nucleic acid samples derived from common respiratory viruses. To validate the assay against full-length SARS-CoV-2 RNA, total viral RNA derived from cell culture supernatant and 19 nasopharyngeal swab samples (8 positive and 11 negative for SARS-CoV-2) were screened. All results were compared to established RT-qPCR assays. Results The 95% detection probability of the RT-RPA assay was determined to be 7.74 (95% CI: 2.87–27.39) RNA copies per reaction. The assay showed no cross-reactivity to any other screened coronaviruses or respiratory viruses of clinical significance. The developed RT-RPA assay produced 100% diagnostic sensitivity and specificity when compared to RT-qPCR (n = 20). Conclusions With a run time of 15 to 20 minutes and first results being available in under 7 minutes for high RNA concentrations, the reported assay constitutes one of the fastest nucleic acid based detection methods for SARS-CoV-2 to date and may provide a simple-to-use alternative to RT-qPCR for first-line screening at the point of need.

Funder

German Federal Ministry of Education and Research

BMBF

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Reference22 articles.

1. A novel coronavirus from patients with pneumonia in China, 2019;Zhu;N Engl J Med,2020

2. A pneumonia outbreak associated with a new coronavirus of probable bat origin;Zhou;Nature,2020

3. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR;Corman;Eurosurveillance,2020

4. Loop-mediated isothermal amplification of DNA;Notomi;Nucleic Acids Res,2000