Dosimetric impact of rotational setup errors in volumetric modulated arc therapy for postoperative cervical cancer

Author:

Tsujii Katsutomo12,Ueda Yoshihiro3,Isono Masaru3,Miyazaki Masayoshi3,Teshima Teruki3,Koizumi Masahiko1

Affiliation:

1. Department of Medical Physics & Engineering, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan

2. Varian Medical Systems, Chuo-ku, Tokyo 103-0026, Japan

3. Department of Radiation Oncology, Osaka International Cancer Institute, Chuo-ku, Osaka 541-8567, Japan

Abstract

Abstract We aimed to evaluate the impact of rotational setup errors on the doses received during postoperative volumetric-modulated arc therapy (VMAT) for cervical cancer. Overall, 121 cone-beam computed tomography (CBCT) sets from 20 patients were rigidly registered to reference computed tomography (CT) sets based on bony landmarks. The rotational setup errors (pitch, yaw and roll) were calculated. Then, 121 CT sets involving rotational setup errors were created, and the dose distribution in these CT sets were recalculated. The recalculated dosimetric parameters for the clinical target volume (CTV) and organs at risk (OAR) were compared to the reference values, and the correlation coefficients between the dosimetric parameter differences and rotational setup errors were calculated. Only the pitch setup error was moderately correlated with CTV coverage (r ≥ 0.40) and strongly correlated with V45 for the bladder (r ≥ 0.91) and V40 for the rectum, small bowel and bone marrow (r ≥ 0.91). The maximum dosimetric difference in a single fraction and overall fractions was −1.59% and −0.69% in D98 for the CTV, 11.72% and 5.17% in V45 for the bladder and −8.03% and −4.68% in V40 for the rectum, respectively. In conclusion, rotational setup errors only slightly impact dose coverage during postoperative cervical cancer VMAT. However, the pitch setup error occasionally affected the doses received by the bladder or the rectum in the overall fraction when the error was systematic. Thus, rotational setup errors should be corrected by adjusting six-degree-of-freedom (DOF) couches to reduce dosimetric differences in the OARs.

Funder

Japan Society for the Promotion of Science KAKENHI

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370