Stability of One-Step Spray-on Splint for Lower Extremity Fractures During Splinting, MEDEVAC, and Impact

Author:

Hobayan C Grace P1,Bates Nathaniel A12ORCID,Heyniger John1,Alzouhayli Kenan1,Piscitani Franco2,Haider Clifton R3,Felton Christopher3,Groth Adam T2,Martin Kevin D2

Affiliation:

1. College of Medicine, The Ohio State University Wexner Medical Center , Columbus, OH 43210, USA

2. Department of Orthopaedics, The Ohio State University Wexner Medical Center , Columbus, OH 43201, USA

3. Special Purpose Processor Development Group, Mayo Clinic , Rochester, MN 55905, USA

Abstract

ABSTRACT Introduction Military transport can induce whole-body vibrations, and combat almost always involves high impact between lower extremities and the ground. Therefore, robust splinting technology is necessary for lower extremity fractures in these settings. Our team compared a novel one-step spray-on foam splint (FastCast) to the current military standard structured aluminum malleable (SAM) splint. Materials and Methods Ten cadaveric specimens were subjected to complete tibia/fibula osteotomy. Specimens were fitted with custom accelerometer and gyroscope sensors superior and inferior to the fracture line. Each specimen underwent fracture and splinting from a standard of care SAM splint and an experimental FastCast spray foam splint in a randomized order. Each specimen was manually transported to an ambulance and then released from a 1 meter height to simulate impact. The custom sensors recorded accelerations and rotations throughout each event. Repeated-measures Friedman tests were used to assess differences between splint method within each event and between sensors within each splint method. Results During splinting, overall summation of change and difference of change between sensors for accelerations and rotations were greater for SAM splints than FastCast across all axes (P ≤ 0.03). During transport, the range of acceleration along the linear superior/inferior axis was greater for SAM splint than FastCast (P = 0.02), as was the range of rotation along the transverse plane (P < 0.01). On impact, the summation of change observed was greater for SAM splint than FastCast with respect to acceleration and rotation on the posterior/anterior and superior/inferior axes (P ≤ 0.03), and the cumulative difference between superior and inferior sensors was greater for SAM than FastCast with respect to anterior-axis rotation (P < 0.05). Conclusion FastCast maintains stabilization of fractured lower extremities during transport and impacts to a significantly greater extent than SAM splints. Therefore, FastCast can potentially reduce the risk of fracture complications following physical stressors associated with combat and extraction.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3