Monitoring Respiratory Rate Continuously Without Attaching a Sensor During a Challenging Ramped Protocol

Author:

Borg Ulf R1ORCID,Antunes André2,Smit Philip2,Addison Paul S2,Montgomery Dean2

Affiliation:

1. Medical Affairs, Medtronic Patient Monitoring , Boulder, CO 80301, USA

2. Medtronic Patient Monitoring, Technopole Centre , Edinburgh, UK

Abstract

ABSTRACT Introduction Respiratory rate (RR) is a crucial vital sign in patient monitoring and is often the best marker of the deterioration of a sick patient. It can be used to help diagnose numerous medical conditions and has been demonstrated to be an independent predictor of patient outcomes in various critical care settings and is incorporated in many clinical early warning scores. Here, we report on the performance of depth-camera-based system for the noncontact monitoring of RR during a ramped RR protocol. The ramped breathing protocol was developed specifically to test the relatively rapid changes in rates, which include clinically important low and high ranges of RRs. Materials and Methods We performed a series of experimental runs with healthy volunteers who were instructed to breathe over a wide range of RRs, where the rates were ramped up from 4 breaths/min to 50 breaths/min then back down to 4 breaths/min in a series of ramped steps. Depth information was acquired from the scene and used to determine a respiratory rate (RRdepth), and this was compared to capnograph or spirometer respiratory rate reference (RRref). A total of 9,482 contemporaneous data pairs (RRdepth, RRref) were collected during the study for comparison. Results A Pearson correlation coefficient of 0.995 was achieved and a line of best fit given by RRdepth = 0.99 × RRref + 0.36 breaths/min. The overall root mean squared difference (RMSD) across the runs was 1.29 breaths/min with a corresponding bias of 0.16 breaths/min, respectively. The associated Bland–Altman analysis found limits of agreement of −2.45 and 2.75 breaths/min. When the data were subdivided according to low, medium, and high RRs, corresponding to ≤10, >10 to 20, and >20 breaths/min, the RMSD accuracies were found to be 0.94, 1.34, and 1.55 breaths/min, respectively. Conclusions The technology performed well, exhibiting an RMSD accuracy well within our target of 3 breaths/min, both across the whole range and across each individual subrange. In summary, our results indicate the potential viability of continuous noncontact monitoring for the determination of RR over a clinically relevant range.

Funder

Medtronic

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3