Microemboli induced by air bubbles may be deposited in organs as a consequence of contamination during medical care

Author:

Forsberg Ulf1,Jonsson Per2,Stegmayr Bernd2

Affiliation:

1. Department of Public Health and Clinical Medicine, Skelleftea Unit, Umea University , Umea, Sweden

2. Unit of Medicine, Umeå University , Umeå, Sweden

Abstract

ABSTRACT Background Larger volumes of accidental air infused during medical care may end up as emboli while microbubbles of air are supposed to be absorbed and cause no harm. The aim of this autopsy study was to investigate if microbubbles of air accidently entering the bloodline may be detected as microemboli (ME) in tissue such as lungs, brain and heart. If so, do differences in prevalence exist between haemodialysis (HD) and amyotrophic lateral sclerosis (ALS) patients. Methods Included were data from 44 patients treated by medical healthcare before death. Twenty-five cases had been treated with chronic HD and 19 cases died from ALS. Since air in the bloodline activates coagulation, ME could appear. To discriminate between microbubbles caused by artificial contamination during autopsy versus microbubbles deposited in vivo, tissues were stained with a polyclonal fluorescent antibody against fibrinogen, fibrin and fragments E and D. Fluorescence staining was used to visualize ME counted within 25 microscopic fields (600×) of a tissue preparation. One tissue preparation was used if available from the lung, heart and frontal lobe of the brain and in five cases also the cerebellum. Results Microbubbles can be verified at autopsy as ME in the lung, heart and brain in tissue from patients exposed to more extensive medical care. There were significantly more ME in the lungs versus the heart or brain. Women had fewer ME than men. The HD group had a higher median of ME per section than the ALS group (lung: 6 versus 3, P = .007; heart: 2.5 versus 1, P = .013; brain: 7.5 versus 2, P = .001) and had more sections with ME findings than the ALS group (P = .002). A correlation existed between the time on HD (months) and ME in the lungs. Conclusions More ME were present in HD patients compared with those who suffered from ALS. Minimizing air contamination from syringes, infusions and bloodlines will decrease ME and subsequent tissue injury.

Funder

Njurföreningarna Norrland

Umeå University

Publisher

Oxford University Press (OUP)

Subject

Transplantation,Nephrology

Reference45 articles.

1. Impact of the intensity of microemboli on neurocognitive outcome following cardiopulmonary bypass;Doganci;Perfusion,2013

2. Microbubbles detection during cardiopulmonary bypass with transoesophageal echocardiography: a case report;Zanatta;Cases J,2008

3. Should air bubble detectors be used to quantify microbubble activity during cardiopulmonary bypass?;Newland;J Extra Corpor Technol,2015

4. A microscopic view of gaseous microbubbles passing a filter screen;Johagen;Int J Artif Organs,2017

5. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis;Stegmayr;Artif Organs,2007

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3