Diameter change in completely remodelled proximal descending aorta after acute type I dissection repair: implications for estimating the pre-dissection size

Author:

Jung Joon Chul1ORCID,Sohn Bongyeon1ORCID,Chang Hyoung Woo1ORCID,Lee Jae Hang1ORCID,Kim Dong Jung1ORCID,Kim Jun Sung1ORCID,Lim Cheong1ORCID,Park Kay-Hyun1ORCID

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Gyeonggi-do, Republic of Korea

Abstract

Abstract OBJECTIVES Pre-dissection diameter of the proximal descending thoracic aorta (p-DTA), if available, would be the reference for determining the size of the stent graft or elephant trunk. Acute type B dissection is known to increase p-DTA diameter by 23% (Rylski factor). This study aimed to investigate the accuracy of estimating post-remodelling diameter of the p-DTA based on the Rylski factor and other post-dissection morphological parameters in acute type I dissection, based on the assumption that the post-remodelling diameter is similar to the pre-dissection diameter. METHODS In 60 patients with acute type I dissection showing complete remodelling of the p-DTA false lumen after surgical repair, preoperative and post-remodelling computed tomography scans were reviewed. Parameters, including maximal true lumen diameter (TLDmax) and aortic area-derived diameter divided by the Rylski factor (AoDRylski), were measured at the p-DTA. RESULTS After complete remodelling, p-DTA diameter decreased by 4.1 mm (P < 0.001). The equivalent to the Rylski factor was 15%. Both TLDmax and AoDRylski frequently showed ≥2 mm discrepancy from post-remodelling aortic diameter (36.7% and 48.3%, respectively, P = 0.30). When 2 parameters coincided within 2 mm, two-third of their estimations were accurate. AoDRylski was more accurate than TLDmax in patients with a large extent of circumferential dissection, and vice versa with less circumferential dissection (P = 0.027). CONCLUSIONS Prediction of post-remodelling aortic diameter relying on a single morphologic parameter carries a substantial risk of overestimation and underestimation. Evaluation based on the extent of circumferential dissection together with the 2 parameters may provide a more reliable estimation.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. New insights into modelling of pre-dissection aortic diameter;European Journal of Cardio-Thoracic Surgery;2021-03-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3