Acute oesophageal safety of high-power short duration with 50 W for atrial fibrillation ablation

Author:

Müller Julian123ORCID,Berkovitz Artur1ORCID,Halbfass Philipp12ORCID,Nentwich Karin12ORCID,Ene Elena1ORCID,Sonne Kai1ORCID,Simu Gelu1,Chakarov Ivalyo1,Barth Sebastian12,Waechter Christian2,Behnes Michael3ORCID,Akin Ibrahim3,Deneke Thomas1ORCID

Affiliation:

1. Clinic for Interventional Electrophysiology, Heart Centre Bad Neustadt, Von-Guttenberg-Straße 11, 97616 Bad Neustadt an der Saale, Germany

2. Department of Cardiology and Angiology, Philipps-University Marburg, Marburg, Germany

3. First Department of Medicine, University Medical Centre Mannheim (UMM), Mannheim, Germany

Abstract

Abstract Aims Pulmonary vein isolation (PVI) using radiofrequency (RF) ablation is an effective treatment option for patients with atrial fibrillation (AF). This study aims to investigate the safety of high-power short duration (HPSD) with emphasis on oesophageal lesions after PVI. Methods and results Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index (AI)-guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) using the ThermoCool SmartTouch SF catheter were included. Patients underwent post-ablation oesophageal endoscopy to detect and categorize thermal oesophageal injury (EDEL). Occurrence and risk factors of oesophageal lesions and perforating complications were analysed. A total of 1033 patients underwent AF ablation with HPSD. Of them, 953 patients (67.6 ± 9.6 years; 58% male; 43% paroxysmal AF; 68% first PVI) underwent post-procedural oesophageal endoscopy and were included in further analyses. Median procedure time was 82.8 ± 24.4 min with ablation times of 16.1 ± 9.2 min. Thermal oesophageal injury was detected in 58 patients (6%) (n = 29 Category 1 erosion, n = 29 Category 2 ulcerous). One patient developed oesophageal perforation (redo, 4th AF ablation). No patient died. Using multivariable regression models, increased total ablation time [odds ratio (OR) 1.029, P = 0.010] and history of stroke (OR 2.619, P = 0.033) were associated with increased incidence of EDEL after AF ablation, whereas increased body mass index was protective (OR 0.980, P = 0.022). Conclusion Thermal oesophageal lesions occur in 6% of HPSD AF ablations. The risk for development of perforating complications seems to be low. Incidence of atrio-oesophageal fistula (0.1%) is comparable to other reported series about RF ablation approaches.

Funder

ESC Training Grant

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com