X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study

Author:

Guillot Marc-Samir1ORCID,Rouchaud Aymeric1ORCID,Mounayer Charbel1,Tricard Jérémy2,Belgacem Alexis3,Auditeau Emilie45,Omraam Olivier45,Fourcade Laurent3,Ballouhey Quentin3ORCID

Affiliation:

1. Department of Radiology, Limoges University Hospital, Limoges, France

2. Department of Thoracic Surgery, Limoges University Hospital, Limoges, France

3. Department of Pediatric Surgery, Limoges University Hospital, Limoges, France

4. INSERM, Limoges University Hospital, IRD, U1094 Tropical Neuroepidemiology, Institute of Epidemiology and Tropical Neurology, GEIST, Limoges, France

5. Department of Epidemiology, Limoges University Hospital, Limoges, France

Abstract

Abstract OBJECTIVES To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia—Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (Pearson coefficient = 0.886; P = 0.033). CONCLUSIONS Non-irradiant pectus deformity assessment is possible in clinical practice, replacing CT with MRI and 3D scanning as a possible readily-accessible monitoring tool.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献