Five-year outcomes of surgical aortic valve replacement with a novel bovine pericardial bioprosthesis

Author:

Chen Jinmiao1ORCID,Lv Minzhi2ORCID,Fu Jiahui1,He Chen1,Guo Yingqiang3,Tao Liang4,Zhou Xinmin5,Gu Tianxiang6,Bartus Krzysztof7,Wei Lai1,Hong Tao1,Wang Chunsheng1

Affiliation:

1. Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University , Shanghai, China

2. Department of Biostatistics, Zhongshan Hospital, Fudan University , Shanghai, China

3. Department of Cardiovascular Surgery, West China Hospital, Sichuan University , Sichuan, China

4. Department of Cardiovascular Surgery, Wuhan Asia Heart Hospital , Hubei, China

5. Department of Cardiovascular Surgery, The Second Xiangya Hospital of Central South University , Hunan, China

6. Department of Cardiovascular Surgery, The First Hospital of China Medical University , Liaoning, China

7. Department of Cardiovascular Surgery and Transplantology, Jagiellonian University Medical College, John Paul II Hospital , Krakow, Poland

Abstract

Abstract OBJECTIVES The short-term performance of the Cingular bovine pericardial aortic valve was proven. This study evaluated its 5-year safety and haemodynamic outcomes. METHODS It enrolled 148 patients who underwent surgical aortic valve replacement with the Cingular bovine pericardial aortic valve between March 2016 and October 2017 in 5 clinical centres in China. Safety and haemodynamic outcomes were followed up to 5 years. The incidence of all-cause mortality, structural valve deterioration and reintervention was estimated by Kaplan–Meier analysis. RESULTS The mean age of patients was 67.7 [standard deviation (SD) 5.1] years, and 36.5% of patients were female. The mean follow-up was 5.3 (SD 1.2) years. Five-year freedom from all-cause mortality, structural valve deterioration and all-cause reintervention were 91.2%, 100% and 99.3%, respectively. At 5 years, the mean gradient and effective orifice area of all sizes combined were 14.0 (SD 5.5) mmHg and 1.9 (SD 0.3) cm2, respectively. For 19- and 21-mm sizes of aortic prostheses, the mean gradients and effective orifice area at 5 years were 17.5 (SD 7.0) mmHg and 1.6 (SD 0.2) cm2 and 13.7 (SD 6.7) mmHg and 1.8 (SD 0.3) cm2, respectively. The incidence of moderate or severe patient–prosthesis mismatch was 4.1% and 0.0% patients at 5 years, respectively. CONCLUSIONS The 5-year safety and haemodynamic outcomes of Cingular bovine pericardial aortic valve are encouraging. Longer-term follow-up is warranted to assess its true durability.

Funder

National Natural Science Foundation of China

Shanghai Rising-Star Program

Publisher

Oxford University Press (OUP)

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3