A Practical Guide for Faecal Calprotectin Measurement: Myths and Realities

Author:

D’Amico Ferdinando12,Nancey Stéphane3,Danese Silvio14,Peyrin-Biroulet Laurent2

Affiliation:

1. Department of Biomedical Sciences, Humanitas University, Milan, Italy

2. Department of Gastroenterology and Inserm NGERE U1256, University Hospital of Nancy, University of Lorraine, Vandoeuvre-lès-Nancy, France

3. Department of Gastroenterology, Hospices Civils de Lyon, Lyon-Sud Hospital, Pierre Benite, and Inserm U1111, CIRI, Lyon, France

4. IBD Center, Department of Gastroenterology, Humanitas Research Hospital, Rozzano -IRCCS-, Milan, Italy

Abstract

Abstract Background and Aims Faecal calprotectin [FC] is a valid and non-invasive marker of mucosal inflammation. It is widely used both in clinical trials and in daily clinical practice for patients with inflammatory bowel diseases, but currently no accepted standardization for FC testing is available. Our primary aim here was to provide a clinician’s guide containing all the practical information on FC measurement in order to avoid any confounding factors, to minimize intra- and inter-individual variability in dosage, and to ensure a better and adequate interpretation of the results. Methods We conducted a detailed search of the scientific literature in the PubMed/MEDLINE, EMBASE and Cochrane databases up to January 2020 to find all relevant and available articles on pre-analytical and analytical phases of FC measurement. Results FC testing is a multi-step procedure consisting of a pre-analytical phase aimed to collect and process the stool sample and a subsequent analytical phase of FC measurement. Several factors can influence test results determining false positives or false negatives. Importantly, this faecal marker is mostly used for patient follow-up and as a predictor of treatment response. For this reason, any altered data may affect the physicians’ decisions, negatively impacting on patient management. Conclusions This review provides for the first time practical advice to minimize dosage variability, although further dedicated studies are needed to compare commercially available tests and identify the best tools for the most precise and accurate FC measurement.

Funder

Gilead

Publisher

Oxford University Press (OUP)

Subject

Gastroenterology,General Medicine

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3