Sensitive detection of <i>n</i>-alkanes using a mixed ionization mode proton-transfer-reaction mass spectrometer

Author:

Amador-Muñoz OmarORCID,Misztal Pawel K.ORCID,Weber Robin,Worton David R.,Zhang HaofeiORCID,Drozd Greg,Goldstein Allen H.ORCID

Abstract

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) is a technique that is widely used to detect volatile organic compounds (VOCs) with proton affinities higher than water. However, n-alkanes generally have a lower proton affinity than water and therefore proton transfer (PT) by reaction with H3O+ is not an effective mechanism for their detection. In this study, we developed a method using a conventional PTR-MS to detect n-alkanes by optimizing ion source and drift tube conditions to vary the relative amounts of different primary ions (H3O+, O2+, NO+) in the reaction chamber (drift tube). There are very few studies on O2+ detection of alkanes and the mixed mode has never been proposed before. We determined the optimum conditions and the resulting reaction mechanisms, allowing detection of n-alkanes from n-pentane to n-tridecane. These compounds are mostly emitted by evaporative/combustion process from fossil fuel use. The charge transfer (CT) mechanism observed with O2+ was the main reaction channel for n-heptane and longer n-alkanes, while for n-pentane and n-hexane the main reaction channel was hydride abstraction (HA). Maximum sensitivities were obtained at low E ∕ N ratios (83 Td), low water flow (2 sccm) and high O2+ ∕ NO+ ratios (Uso =  180 V). Isotopic 13C contribution was taken into account by subtracting fractions of the preceding 12C ion signal based on the number of carbon atoms and the natural abundance of 13C (i.e., 5.6 % for n-pentane and 14.5 % for n-tridecane). After accounting for isotopic distributions, we found that PT cannot be observed for n-alkanes smaller than n-decane. Instead, protonated water clusters of n-alkanes (M  ⋅  H3O+) species were observed with higher abundance using lower O2+ and higher water cluster fractions. M  ⋅  H3O+ species are probably the source for the M + H+ species observed from n-decane to n-tridecane. Normalized sensitivities to O2+ or to the sum of O2++ NO+ were determined to be a good metric with which to compare sensitivities for n-alkane detection between experiments. Double hydride abstraction was observed from the reaction with O2+. Sensitivity to CT increased with carbon chain length from n-pentane to n-dodecane, sensitivity to HA increased from n-heptane to n-dodecane and sensitivity to PT increased from n-decane to n-tridecane. Sensitivity to CT exponentially decreased with molecular ionization energy, which is inversely related to the carbon chain length. We introduce a calibrated fragmentation algorithm as a method to determine the concentrations of n-alkanes and demonstrate its effectiveness using a custom n-alkane mixture and a much more complex oil example representing perhaps the most difficult mixture available for application of the method. We define optimum conditions for using the mixed ionization mode to measure n-alkanes in conventional PTR-MS instruments regardless of whether they are equipped with switchable reagent ion (SRI) capabilities.

Publisher

Copernicus GmbH

Subject

Atmospheric Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3