Abstract
Semi-automatic and automatic pulsed gas metal arc welding (GMAW) of aluminium alloy 5083 with ER5356 filler wire causes considerable softening in the weld. The tensile strength of dressed automatic welds approaches that of the base metal, but the stress concentration caused by the weld toe in undressed semi-automatic welds reduced the tensile strength significantly. Fully automatic welds displayed improved fatigue properties compared to semi-automatic welds.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference5 articles.
1. Wilcox D. V, Adkins H., Dickerson P.B., Hasemeyer E.A. & Lockwood L. Welding Aluminum. Florida: American welding society. 1972 6 th edition.
2. P.P. Lean, L. Gil, A. Ureña: Jour. Matria. Proces. Techno. 143-144 (2003), pp.846-850.
3. C. Zhou, X. Yang and G. Luan: Scripta Materialia 53 (2005), pp.1187-1191.
4. ASTM Standard B557, 2002, Test methods of tension testing wrought and cast aluminium- and magnesium-alloy products, ASTM International, West Conshohocken, PA, 2002, DOI: 10. 1520/B0557-02.
5. ASTM Standard E466, 2002, Practice for conducting force controlled constant amplitude axial fatigue tests of metallic materials, ASTM International, West Conshohocken, PA, 2002, DOI: 10. 1520/E0466-02a.