Affiliation:
1. Chongqing Electric Power Research Institute
2. China State Construction Technical Center
Abstract
In the nonlinear time-history analysis for high-rise building, different damping models may lead to results with great difference. Limited by the stable time increment, the stiffness proportional damping is usually neglected in Abaqus/Explicit, and only a simplified mass proportional damping is used, which can be derived from the fundamental frequency and the critical damping factor. In this paper, the influence on the results of this method has been researched by numerical examples, the numerical results also show that the stiffness proportional damping cannot be neglected. Based on these comparisons, a more reasonable damping model is presented for improving the results of high frequencies.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. R. Clough, J. Penzien. Dynamics of Structures, McGraw Hill Kogakusha (1975).
2. Code for Seismic Design of Buildings. Beijing, China (2010).
3. EL. Wilson, Three-Dimensional Static and Dynamic Analysis of Structures: a Physical Approach with Emphasis on Earthquake Engineering. Computers and Structures (1998).
4. R. E. Spears, S. R. Jensen Approach for selection of Rayleigh damping parameters used for tiem history analysis. 2009 ASME Pressure Vessels and Piping Division Conference, July 26-30, Prague, Czech Republic (2009).
5. Indrajit Chowdhury, Shambhu P. Dasgupta. Computation of Rayleigh damping coefficients for large systems. The Electronic Journal of Geotechnical Engineering, Vol(8) (2003).
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献