Intranipple injection with methylene blue for tracing axillary sentinel lymph nodes in rats: A preliminary feasibility study

Author:

Qu FengjiangORCID, ,Wu DiORCID,Fan ZhiminORCID,Hu ChenyangORCID,Ma JinxiuORCID,Zervoudis StefanosORCID,Wang XiaozhenORCID, , , , , , , ,

Abstract

Background and purpose: Investigate the feasibility of intranipple injection (INN) of methylene blue dye (MB) for tracing the axillary sentinel lymph node (SLN) in rats, to provide different injection methods for finding SLN injection tracers and offer an experimental basis for specific localization of SLN. Methods: Eleven Sprague-Dawley female rats with body masses of 150-400g. Ten rats were randomly selected to use the third pair of mammary glands as the tracer injection site, and the left side was injected with MB (0.05 mL, 1% concentration) by intracutaneous injection of areola (IAA), while the right side was injected with MB(0.05 mL, 1% concentration) by INN. After 5 minutes, the rats were dislocated and dissected, and the blue-stained SLNs were found and recorded, The effectiveness evaluation was based on the number and rate of detection of SLNs as indicators, and the differences between the indicators of the two injection methods of IAA and INN were compared and analyzed. The safety evaluation was based on whether the nipple showed blood flow disorders and necrosis after MB injection by INN in the remaining 1 rat as the criteria. The data were stored and analyzed using Microsoft Excel and SPSS 25.0 statistical software. Νon-normally distributed measurement data were expressed as M (Q1, Q3) and compared by rank sum test, and count data were expressed as cases or percentages and compared by 2 test. p < 0.05 was considered a statistically significant difference. Results: (i)100% (10/10) detection rate of SLNs by applying MB to both INN and IAA modalities;(ii) median number of SLNs detection was 2.0 (1.0,2.0) vs. 1.5 (1.0,2.0) for INN and IAA, respectively (P=0.66), and the difference was not statistically significant;(iii) No nipple necrosis was observed for 4 consecutive days after INN with MB. Conclusion: Tracer detection of SLNs by INN injection in rats is feasible, and the detection rate of SLNs by INN is the same as that of IAA; there is no significant difference in the median number of detected SLNs between the two injection methods. No nipple necrosis was observed after INN with MB.
同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3